We have built Multigap Resistive Plate Chambers (MRPC) with six 300 mm gas gaps and an active area of 158 ร 82 cm 2 . The signals are generated on 2.5 cm wide copper pickup strips; these are read out at each end thus allowing the position of the hit along the strip to be obtained from the time diffe
A cosmic ray test system has been built to fully qualify the resistive plate chambers for the MUON system of the BESIII experiment. The setup has been designed to measure detector's performance and to verify the stability and reliability of the MUON system. The same electronics, similar readout meth