๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Required accuracy of inductance measurement for current imbalance phenomena

โœ Scribed by S Yamaguchi; S Takayama; Y Hasegawa; A Ninomiya; K Nakamura; H Okumura; Ryu Shimada


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
702 KB
Volume
41
Category
Article
ISSN
0011-2275

No coin nor oath required. For personal study only.

โœฆ Synopsis


Current imbalance can be estimated by the solution of the circuit equation, which depends on the result of the measurement of the self-and mutual inductances. Strand circuit is coupled with each other strongly, and therefore the matrix calculation is stiff. This situation leads to enhance the error of the measurement. In order to study this problem, we made a magnet, in which the cable was composed of the nine insulated strands, and measured the inductance matrix of the strand circuits by the LCR-meter. The inductance of the magnet is 11 mH, and the error of the measurement is the order of micro Henry to 10 lH. The average coupling factor of the magnet is 0.9956, and therefore this inductance matrix is almost singular. Finally, we calculated the currents of the strand. The accuracy of the inductance measurement is the order of 5-6 digits. We used eMathematica to solve the circuit equation, and we tested the accuracy of the calculation precision. Random number method is introduced to estimate the required accuracy of the inductance measurement. The required accuracy of the inductance measurement is the order of micro Henry in this magnet to obtain the accuracy of 5% for the strand currents.


๐Ÿ“œ SIMILAR VOLUMES


Numerical simulation of inductive method
โœ A. Kamitani; T. Takayama; S. Ikuno ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 366 KB

The inductive method for measuring the critical current density in a high-temperature superconducting (HTS) bulk has been investigated numerically. In the method, an ac current is applied in a small coil placed just above a HTS bulk and, simultaneously, the third-harmonic voltage V 3 induced in the

Dose requirements, assay procedures and
โœ Thomas K. Wong; Toni E. Blanton; Colleen K. Hunnicutt; David L. Shore; Richard B ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 957 KB

Pregnant Sprague-Dawley and Fisher 344 rats were treated on day 15 of gestation with Aroclor 1254 in a single dose ranging from 0 to 500 mg kg-1 body weight and killed on day 18 of gestation. In the small groups of animals used for this study, no effect was observed on mean maternal liver or placent