Reproducibility of lateral spine scans using dual energy X-ray absorptiometry

✍ Scribed by T. A. Larnach; S. J. Boyd; R. C. Smart; S. P. Butler; P. G. Rohl; T. H. Diamond


Publisher
Springer
Year
1992
Tongue
English
Weight
594 KB
Volume
51
Category
Article
ISSN
1432-0827

No coin nor oath required. For personal study only.

✦ Synopsis


Reproducibility of lateral spine dual energy X-ray absorptiometry (LAT DEXA) scans using a Lunar DPX-L scanner was assessed in a cadaveric phantom and in patients. One hundred phantom measurements over 7 months demonstrated a longitudinal stability of 1.7% (coefficient of variation, CV). Additional scans were performed with the phantom rotated by up to 20 degrees in each of the three orthogonal planes to assess the effects of variable patient positioning. Horizontal and vertical rotation of the spine had little effect on the estimated bone mineral density (BMD), however, axial rotation of greater than 8 degrees led to errors in the BMD measurement. One hundred consecutive patients had two lateral scans performed within 1 month. BMD (range 0.10-1.6 g/cm2) was determined for each scan by one operator. Significant overlap from ribs and pelvis was often seen with L2 and L4 vertebrae but one vertebra (L3) could be measured in every case. Intraoperator and interoperator variability was assessed by three experienced operators, each analyzing 10 patients' scans on five separate occasions, and was found to be less than 1.1% for a single vertebra. BMD estimation of vertebral bodies and midslices by lateral DEXA scans (CV% of 3.8% and 4.6%) have a 95% confidence interval of 0.074 g/cm2 and 0.096 g/cm2, respectively for two vertebrae. This variability is due mainly to axial rotation, with operator variability, horizontal rotation, and vertical rotation having little effect on BMD estimation.


πŸ“œ SIMILAR VOLUMES


Clinical reproducibility of dual energy
✍ Pamela Williams-Russo; John H. Healey; Ted P. Szatrowski; Robert Schneider; Step πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 663 KB

## Abstract Dual energy x‐ray absorptiometry is a technique advocated for the measurement of bone mass throughout the skeleton, and recently it has been used to measure changes in periprosthetic bone mass after joint replacement. The accuracy and precision of the method in clinical patient populati

Lateral spine dual-energy X-ray absorpti
✍ H. Franck; M. Munz; M. Scherrer; H. V. Lilienfeld-Toal πŸ“‚ Article πŸ“… 1995 πŸ› Springer 🌐 English βš– 409 KB

Recently, fan beam (FB) designs have been made available by several manufacturers (Aloka, Hologic Lunar and Sophar) to measure lumbar spine bone mineral area density (BMD) in both an anteroposterior (AP) and a lateral projection. The present study was performed to evaluate some characteristics of a