𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Reproducibility of fMRI at 1.5 T in a strictly controlled motor task

✍ Scribed by Jing Z. Liu; Luduan Zhang; Robert W. Brown; Guang H. Yue


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
704 KB
Volume
52
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Reproducibility of functional MRI (fMRI) data has been controversial. This issue was examined in this study by evaluating a strictly controlled voluntary force‐matching handgrip task. Handgrip force, electromyogram (EMG), and fMRI data of brain activity were simultaneously recorded during the task performance. The task was repeated three times in each of the two experimental sessions. While force remained unchanged and EMG showed little variation across trials and sessions, the results revealed that fMRI‐measured brain signals varied significantly among individual trials. However, the averaged fMRI signals over the three trials did not show significant difference between the two sessions. Our data suggest that fMRI is better at defining brain activation qualitatively than quantitatively, i.e., the locations of the activation areas could be reproduced quite reliably while their sizes fluctuated substantially. Magn Reson Med 52:751–760, 2004. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


EPI-BOLD fMRI of human motor cortex at 1
✍ Francesco Fera; Martin N. Yongbi; Peter van Gelderen; Joseph A. Frank; Venkata S 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 523 KB

## Abstract ## Purpose To investigate the sensitivity dependence of BOLD functional imaging on MRI acquisition parameters in motor stimulation experiments using a finger tapping paradigm. ## Materials and Methods Gradient‐echo echo‐planar fMRI experiments were performed at 1.5 T and 3.0 T with v

Spatial location and strength of BOLD ac
✍ J. Harmer; R. M. Sanchez-Panchuelo; R. Bowtell; S. T. Francis 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 484 KB

The increased blood oxygenation level-dependent contrast-to-noise ratio at ultrahigh field (7 T) has been exploited in a comparison of the spatial location and strength of activation in high-resolution (1.5 mm isotropic) gradient echo (GE) and spin echo (SE), echo planar imaging data acquired during

Comparison of spiral imaging and SENSE-E
✍ Jeff D. Winter; Julien Poublanc; Adrian P. Crawley; Andrea Kassner 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 639 KB

## Abstract ## Purpose To quantitatively compare spiral imaging and sensitivity‐encoded‐echo‐planar‐imaging (SENSE‐EPI) methods for blood oxygen level‐dependent (BOLD) imaging using controlled changes in the end‐tidal partial pressure of CO~2~ (PetCO~2~) to provide a global BOLD response. Specific

Short echo time 1H MRSI of the human bra
✍ Jannie P. Wijnen; Jack J.A. van Asten; Dennis W.J. Klomp; Torill E. Sjobakk; Ing 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 356 KB 👁 1 views

## Abstract ## Purpose: To assess the reproducibility of ^1^H‐MR spectroscopic imaging (MRSI) of the human brain at 3T with volume selection by a double spin echo sequence for localization with adiabatic refocusing pulses (semi‐LASER). ## Materials and Methods: Twenty volunteers in two different