𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Reproducibility of diffusion tensor imaging in human forearm muscles at 3.0 T in a clinical setting

✍ Scribed by Martijn Froeling; Jos Oudeman; Sandra van den Berg; Klaas Nicolay; Mario Maas; Gustav J. Strijkers; Maarten R. Drost; Aart J. Nederveen


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
484 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The aim of the present study was to evaluate a fast clinical protocol to enable diffusion tensor imaging of the human forearm and assess the reproducibility of six diffusion tensor imaging parameters, i.e., the tensor eigenvalues (λ~1~, λ~2~, and λ~3~), mean diffusivity, fractional anisotropy, and ellipsoid eccentricity. The right forearms of 10 healthy volunteers were scanned twice, with a 1‐week interval. Reproducibility of the diffusion tensor imaging parameters was interpreted using Bland‐Altman plots, coefficient of repeatability, repeatability index, and the intraclass correlation coefficient. Analysis was done for three regions of interest: the whole muscle volume, flexor digitorum profundus, and extensor digitorum. The Bland‐Altman analysis showed that there is good agreement between the two measurements. Based on the intraclass correlation coefficients, agreement was substantial (0.59 < intraclass correlation coefficient < 0.92) for all six parameters of the whole muscle volume and flexor digitorum profundus but only fair (0.18 < intraclass correlation coefficient < 0.64) for the extensor digitorum. Using a 7 min 40 sec scan protocol, which was well tolerated by the volunteers, the reproducibility of diffusion tensor imaging parameters was demonstrated. However, repeatability varies, depending on the region of interest and diffusion tensor imaging parameters. This should be taken into account when a longitudinal study is designed. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Imaging of single human carcinoma cells
✍ Jens Pinkernelle; Ulf Teichgräber; Fabian Neumann; Lukas Lehmkuhl; Jens Ricke; R 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 234 KB

## Abstract The purpose of the present study was to examine whether single human carcinoma cells labeled with iron oxide nanoparticles could be detected by magnetic resonance (MR) imaging on a clinical 3‐T scanner using a surface coil only. WiDr human colon carcinoma cells were loaded with two kind

Diffusion tensor imaging (DTI) of rodent
✍ Francis K.H. Lee; Ma-Rong Fang; Gregory E. Antonio; David K.W. Yeung; Edward T.Y 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 285 KB 👁 1 views

## Abstract ## Purpose To evaluate the feasibility of using a clinical 1.5T MR scanner to perform magnetic resonance (MR) diffusion tensor imaging (DTI) on in vivo rodent brains and to trace major rodent neuronal bundles with anatomical correlation. ## Materials and Methods Two normal adult Spra

Diffusion tensor imaging of in vivo and
✍ Saaussan Madi; Khader M. Hasan; Ponnada A. Narayana 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 318 KB

## Abstract Regional values of fractional anisotropy (FA) and mean diffusivity (__D__~av~) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) read

Short echo time 1H MRSI of the human bra
✍ Jannie P. Wijnen; Jack J.A. van Asten; Dennis W.J. Klomp; Torill E. Sjobakk; Ing 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 356 KB 👁 1 views

## Abstract ## Purpose: To assess the reproducibility of ^1^H‐MR spectroscopic imaging (MRSI) of the human brain at 3T with volume selection by a double spin echo sequence for localization with adiabatic refocusing pulses (semi‐LASER). ## Materials and Methods: Twenty volunteers in two different