𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait

✍ Scribed by Dr. M. P. Kadaba; H. K. Ramakrishnan; M. E. Wootten; J. Gainey; G. Gorton; G. V. B. Cochran


Publisher
Elsevier Science
Year
1989
Tongue
English
Weight
937 KB
Volume
7
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


The repeatability of gait variables is an important consideration in the clinical use of results of quantitative gait analysis. Statistical measures were used to evaluate repeatability of kinematic, kinetic, and electromyographic data waveforms and spatiotemporal parameters of 40 normal subjects. Subjects were evaluated three times on each test day and on three different test days while walking at their preferred or natural speed. Intrasubject repeatability was excellent for kinematic data in the sagittal plane both within a test day as well as between test days. For joint angle motion in the frontal and transverse planes, the repeatability was good within a test day and poor between test days. Poor between-day repeatability of joint angle motion in the frontal and transverse planes was noted to be partly due to variabilities in the alignment of markers. Vertical reaction and fore-aft shear forces were more repeatable than the mediolateral shear force. Sagittal plane joint moments were more repeatable than frontal or transverse plane moments. For electromyographic data, repeatability within a day was slightly better than between test days. In general, the results demonstrate that with the subjects walking at their natural or preferred speed, the gait variables are quite repeatable. These observations suggest that it may be reasonable to base significant clinical decisions on the results of a single gait evaluation.


πŸ“œ SIMILAR VOLUMES


In vivo kinematics and kinetics of a bi-
✍ Fabio Catani; Andrea Ensini; Claudio Belvedere; Alessandro Feliciangeli; Maria G πŸ“‚ Article πŸ“… 2009 πŸ› Elsevier Science 🌐 English βš– 221 KB

## Abstract After total knee arthroplasty, changes in articular surface geometry, soft tissue treatment, and component alignment can alter normal lower limb function. The guided motion bi‐cruciate substituting prosthesis was designed specifically to restore physiological knee joint motion. We deter

Lower limb alignment and foot angle are
✍ Michelle Andrews; Frank R. Noyes; Timothy E. Hewett; Thomas P. Andriacchi πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 708 KB

## Abstract Anatomic and mechanical factors that affect loading in the knee joint can contribute to pathologic changes seen at the knee in degenerative joint disease and should be considered in treatment planning. The objectives of this study were to quantify the relationships between the alignment