In prior work, we examined the removal of abietic acid films from rotating fiberglass laminate disks by aqueous solutions of a nonionic surfactant. A three-stage cleaning mechanism was found, consisting successively of solubilization, shear-driven cleaning, and roll-up. We extend this work by explor
Removal of Solid Organic Films from Rotating Disks Using Emulsion Cleaners
✍ Scribed by J.A. Kabin; S.T. Withers; C.S. Grant; R.G. Carbonell; A.E. Sáez
- Publisher
- Elsevier Science
- Year
- 2000
- Tongue
- English
- Weight
- 583 KB
- Volume
- 228
- Category
- Article
- ISSN
- 0021-9797
No coin nor oath required. For personal study only.
✦ Synopsis
Measurements have been made of the rate of removal of a solid organic film (phenanthrene) from the surface of a rotating disk using emulsions containing water, the nonionic surfactant Tween 20, and d-limonene as the organic phase. The results show that phenanthrene removal initially occurs by the uptake of phenanthrene into the emulsion drops as small aggregates. Simultaneously, the organic phase penetrates into the phenanthrene film, diminishing the adhesive force between the film and the substrate. After sufficient time, the phenanthrene film detaches from the rotating disk surface as a solid. This detachment mechanism accounts for the vast majority of the phenanthrene removal (∼90%). Initial solubilization rates were analyzed using two solubilization models. Both models assume that phenanthrene removal occurs via a mass transfer limited removal of phenanthrene-laden emulsion drops from the phenanthrene film surface into the bulk solution. One model treats the emulsion as homogeneous while the other accounts for the finite size of the emulsion droplets. The latter model was also used to relate the flux of organic phase impacting the phenanthrene film to the detachment times.
📜 SIMILAR VOLUMES