Remarks on forced convection heat transfer in liquid nitrogen and neon
✍ Scribed by L. Bewilogua; R. Knöner
- Book ID
- 104111193
- Publisher
- Elsevier Science
- Year
- 1980
- Tongue
- English
- Weight
- 168 KB
- Volume
- 20
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
✦ Synopsis
copper flanges, no leakage was detected with the range of the sensitivity of the detector, 2.3 x 10 -~~ arm cm~s -~ div -~. In tltis test, it was found tlmt both silver.plated and Teflon-coated O-rings, which had once been used and dismounted, could satisfactorily be used in superfluid helium at least once more. Seals with O-rings neither silver-plated nor Teflon-coated were not leak-tight even at room temperature; accordingly, the plating with giver or coating with Teflon is essential for ensuring leak. tight seals.
📜 SIMILAR VOLUMES
THE heat transfer coefficient in liquid hydrogen, liquid neon, liquid nitrogen, and liquid argon in the range of free convection and bubble-boiling has been measured. Two small tubes of diameter 0.6 and 3.0 mm in the form of horizontally suspended