Reliability study of the sonographic measurement of the acromiohumeral distance in symptomatic patients
β Scribed by B. G. Pijls; F. P. Kok; L. I. F. Penning; N. A. Guldemond; H. J. Arens
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 202 KB
- Volume
- 38
- Category
- Article
- ISSN
- 0091-2751
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Background.
The purpose of this study was to evaluate the interβ and intraβobserver reliability and accuracy of sonographic (US) acromiohumeral distance (AHD) measurement for both experienced and novice operators in US in patients suffering from subacromial impingement syndrome.
Method.
A total of 43 patients (50 shoulders) diagnosed with subacromial impingement syndrome were recruited from an orthopedic outpatient clinic. The US measurement of AHD was obtained consecutively in a neutral position and in a 60Β° abduction position. A total of 300 blinded measurements were taken.
Result.
In the neutral abduction group the intraβ observer interclass correlation coefficient (ICC) was 0.94 for the experienced operator and 0.92 for the novice operator. The interβobserver ICC was 0.70 and the accuracy was 1.1 mm. In the 60Β° abduction group, the intraβobserver ICC was 0.90 for the experienced operator and 0.87 for the novice operator. The interβobserver ICC was 0.64 and the accuracy was 1.4 mm. All ICCs were significant at a level of p < 0.0001.
Conclusion.
The inaccuracy of the method was 1 mm regardless of the experience of the observer. US AHD measurement in patients with shoulder complaints is not as accurate as reported in healthy subjects. This may have important implications for the clinical use of this parameter. Β© 2010 Wiley Periodicals, Inc. J Clin Ultrasound, 2010
π SIMILAR VOLUMES
## Abstract Sonography is increasingly being used for assessment in tennis elbow research and clinical practice, but there are a lack of data regarding its validity, reliability, and responsiveness to change for this application. Studies using the modality were reviewed to establish current levels
The test-retest and split-half ,reliability of flicker threshold measurement was determined in 23 female and three male patients with primary degenerative dementia of the Alzheimer's type (PDDAT). Patients had a mean age of 81.7 f 6.05 years (range 67-89). Diagnosis of PDDAT was based on DSM-IIIR cr
Fetal renal size late in the first trimester of pregnancy was evaluated by transvaginal ultrasonography in 50 patients not at risk for congenital kidney disease and whose pregnancies resulted in a normal outcome. Both kidneys were reliably identified in all patients scanned at 12 weeks, 13 weeks, an
Objective: To determine whether bioelectrical impedance analysis (BIA) is a valid measure of change in body fat in anorexia nervosa (AN) patients during refeeding, as compared to skin fold calipers (SF). Methods: Prospective cohort study with measures of BIA and SF performed once a month for 3 month