𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Reliability of brain volumes from multicenter MRI acquisition: A calibration study

✍ Scribed by Hugo G. Schnack; Neeltje E.M. van Haren; Hilleke E. Hulshoff Pol; Marco Picchioni; Matthias Weisbrod; Heinrich Sauer; Tyrone Cannon; Matti Huttunen; Robin Murray; René S. Kahn


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
257 KB
Volume
22
Category
Article
ISSN
1065-9471

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Multicenter studies can provide additional information over single center studies because of their increased statistical power. Because similar acquisition protocols are being used internationally for structural magnetic resonance imaging (MRI) studies of the human brain, volumetric MRI data studies seem suitable for this purpose. Possible systematic differences between sites should be avoided, however, particularly when subtle differences in tissue volume are being searched for, such as in neuropsychiatric diseases. In this calibration study, the brains of six healthy volunteers were (re)scanned with MR scanners from four different manufacturers at five different sites, using the local acquisition protocols. The images were segmented at a central reference site. The intraclass correlation coefficient (ICC) was determined for the whole brain, gray and white matter, cerebellum, and lateral and third ventricle volumes. When required, the processing algorithms were calibrated for each site. Calibration of the histogram analysis was needed for segmentation of total brain volume at one site and for gray and white matter volume at all sites. No (additional) calibration was needed for cerebellum and ventricle volumes. The ICCs were ≥0.96 for total brain, ≥0.92 for cerebellum, ≥0.96 for lateral ventricle, ≥0.21 for third ventricle, ≥0.84 for gray matter, and ≥0.78 for white matter volume. Calibration of segmentation procedures allows morphologic MRI data acquired at different research sites to be combined reliably in multicenter studies. Hum. Brain Mapping 22:312–320, 2004. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Scan–rescan reliability of subcortical b
✍ Rajendra A. Morey; Elizabeth S. Selgrade; Henry Ryan Wagner II; Scott A. Huettel 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 596 KB

## Abstract Large‐scale longitudinal studies of regional brain volume require reliable quantification using automated segmentation and labeling. However, repeated MR scanning of the same subject, even if using the same scanner and acquisition parameters, does not result in identical images due to s

Evaluation of cardiac biventricular segm
✍ Jyrki M.P. Lötjönen; Vesa M. Järvinen; Benjamin Cheong; Edwin Wu; Sari Kivistö; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 880 KB

## Abstract ## Purpose To validate a volumetric biventricular segmentation solution for multiaxis cardiac magnetic resonance (CMR) images. ## Materials and Methods The study population comprised 40 subjects. Biventricular end‐diastolic and ‐systolic phases were segmented from both short‐axis and

A longitudinal observational study of br
✍ Juha Martola; Jakob Bergström; Sten Fredrikson; Leszek Stawiarz; Jan Hillert; Yi 📂 Article 📅 2009 🏛 Springer 🌐 English ⚖ 317 KB

## Introduction: Multiple sclerosis (ms) has a variable progression with an early onset of atrophy. individual longitudinal radiological evaluations (over decades) are difficult to perform due to the limited availability of magnetic resonance imaging (mri) in the past, patients lost in follow-up, a