𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Reduction of noise in diffusion tensor images using anisotropic smoothing

✍ Scribed by Zhaohua Ding; John C. Gore; Adam W. Anderson


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
931 KB
Volume
53
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

To improve the accuracy of tissue structural and architectural characterization with diffusion tensor imaging, a novel smoothing technique is developed for reducing noise in diffusion tensor images. The technique extends the traditional anisotropic diffusion filtering method by allowing isotropic smoothing within homogeneous regions and anisotropic smoothing along structure boundaries. This is particularly useful for smoothing diffusion tensor images in which direction information contained in the tensor needs to be restored following noise corruption and preserved around tissue boundaries. The effectiveness of this technique is quantitatively studied with experiments on simulated and human in vivo diffusion tensor data. Illustrative results demonstrate that the anisotropic smoothing technique developed can significantly reduce the impact of noise on the direction as well as anisotropy measures of the diffusion tensor images. Magn Reson Med 53:485–490, 2005. Β© 2005 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


Smoothing that does not blur: Effects of
✍ Marta Moraschi; Gisela E. Hagberg; Margherita Di Paola; Gianfranco Spalletta; Br πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 287 KB

## Abstract ## Purpose: To compare the effects of anisotropic and Gaussian smoothing on the outcomes of diffusion tensor imaging (DTI) voxel‐based (VB) analyses in the clinic, in terms of signal‐to‐noise ratio (SNR) enhancement and directional information and boundary structures preservation. ##

Contribution of cardiac-induced brain pu
✍ Minzhi Gui; Ashish A. Tamhane; Konstantinos Arfanakis πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 152 KB πŸ‘ 1 views

## Abstract ## Purpose To assess the effects of cardiac‐induced brain pulsation on the noise of the diffusion tensor in Turboprop (a form of periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER] imaging) diffusion tensor imaging (DTI). ## Materials and Methods

Comparison of Scalar Measures Used in Ma
✍ Mark M. Bahn πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 356 KB

The tensors derived from diffusion tensor imaging describe complex diffusion in tissues. However, it is difficult to compare tensors directly or to produce images that contain all of the information of the tensor. Therefore, it is convenient to produce scalar measures that extract desired aspects of

Correction of eddy-current distortions i
✍ Jiancheng Zhuang; Jan Hrabe; Alayar Kangarlu; Dongrong Xu; Ravi Bansal; Craig A. πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 467 KB πŸ‘ 1 views

## Abstract ## Purpose To correct eddy‐current artifacts in diffusion tensor (DT) images without the need to obtain auxiliary scans for the sole purpose of correction. ## Materials and Methods DT images are susceptible to distortions caused by eddy currents induced by large diffusion gradients.

Regional alterations of brain microstruc
✍ Wang Zhan; Gail A. Kang; Graham A. Glass; Yu Zhang; Cheryl Shirley; Rachel Milli πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 467 KB πŸ‘ 1 views

## Abstract This study tested the hypothesis that diffusion tensor imaging can detect alteration in microscopic integrity of white matter and basal ganglia regions known to be involved in Parkinson's disease (PD) pathology. It was also hypothesized that there is an association between diffusion abn