Reducing superheater corrosion in wood-fired boilers
✍ Scribed by P. Henderson; P. Szakálos; R. Pettersson; C. Andersson; J. Högberg
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- German
- Weight
- 362 KB
- Volume
- 57
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
One of the major drawbacks to the combustion of 100% biomass in power station boilers is the increase in the fouling and corrosion of superheaters. Experience shows that conventional superheater steels last no more than 20 000 h or four operating years before they must be replaced, if 100% wood‐based fuel is used and the steam temperature is higher than 480°C. Rapid corrosion of superheaters leads to increased maintenance costs while widespread deposit formation gives rise to a decrease in efficiency of the turbine and an increase in unplanned outages. This paper reports on measures taken to reduce superheater corrosion.
Most biomass fuels have a high content of alkali metals and chlorine, but they contain very little sulphur compared to fossil fuels. Potassium chloride, KCl, is found in the gas phase, condenses on the superheater tubes and forms complex alkali salts with iron and other elements in the steels. These salts have low melting points and are very corrosive. The corrosion can be mitigated by use of an instrument for in‐situ measurement of alkali chlorides in the flue gases, in combination with the addition of ammonium sulphate. An ammonium sulphate solution, specially developed for the reduction of corrosion was sprayed into the flue gases and effectively converted KCl into potassium sulphate, K~2~SO~4~, much less corrosive than KCl.
Deposit probe tests and long‐term corrosion probe tests have been performed in‐situ in two biomass‐fired fluidised bed boilers. One boiler, 105 MW~tot~, 540 °C steam, is the CHP plant in Nyköping, Sweden. The other producing 98 MW~tot~, 480 °C steam, is a bark‐fired boiler at a pulp and paper mill in Munksund, also in Sweden. Tests have been performed with a range of steel types, ferritic and austenitic, with ammonium sulphate additive and under normal conditions (no additive). Corrosion rates have been measured, deposit chemistry analysed and flue gas chemistry and KCl content measured. The structure and composition of the oxide with and without ammonium sulphate has been investigated. The results show that ammonium sulphate reduced the KCl levels in the flue gases, removed the chlorides from the deposits and the metal/oxide interface, greatly reduced the deposition rates and halved the corrosion rates for superheater materials. The alkali chloride measuring system and the use of ammonium sulphate for the reduction of corrosion have now been patented.
📜 SIMILAR VOLUMES
## Abstract Two full scale superheaters were exposed in the loop seal of a 30 MW wood‐fired CFB plant in Nässjö, Sweden, for one firing season each. Some austenitic steel tubes from the first tube bundle were reinstalled in the second superheater. The superheater tubes were made from one ferritic s
The corrosion was investigated on a superheater test coil in a CFB waste boiler. The alloys ranged from ferritic steel T22 to nickel-based Alloy 65 and the metal temperatures were between 460 and 540 8C. The thickness of the deposit was alloy and temperature dependent. The low-alloyed steels develop
This study concerns the scales formed on the steels T22 , Alloy 310, Alloy 28 and the nickel-based Alloy 65 in a superheater test coil at 460 -540 8C in a CFB waste boiler. The methods used for the characterisation of the scales included SEM, EDX, Auger spectroscopy and XRD. The deposits on the tube