## Abstract Single‐slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is
Reduced slab boundary artifact in multi-slab 3D fast spin-echo imaging
✍ Scribed by Kecheng Liu; Yansun Xu; Mark Loncar
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 324 KB
- Volume
- 44
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
The three-dimensional multi-slab fast spin-echo (3DFSE) sequence is a time-efficient technique for volume scanning which provides images with a good signal-to-noise ratio, adjustable contrast weighting, and high spatial resolution. Unfortunately, it suffers from slice-to-slice amplitude variation associated with imperfect slab definition. This slab boundary artifact becomes especially apparent when multiplanner reformatting is used to create alternate anatomical views. The shifted interleaved multi-volume acquisition (SIMVA) described here suppresses slab boundary artifact in image space. It displaces each slab (RF excitation) position incrementally along the slice (z) axis, in coordination with the primary phase encode step, so that the slab boundary artifact is converted into a correctable amplitude modulation in the primary phase encode direction (k(Y)-axis). After the Fourier transform in primary phase encoding, the slab boundary artifact is mapped into a different and less severe artifact on a different spatial axis. Preliminary measurements show that SIMVA reduces the slab boundary artifact by an order of magnitude in multiplanar reformatted views. Magn Reson Med 44:269-276, 2000.
📜 SIMILAR VOLUMES
## Abstract __T__~1~‐weighted contrast is conventionally obtained using multislice two‐dimensional (2D) spin‐echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high‐energy deposition.
## Abstract Conventional __T__~2~‐weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid‐attenuated inversion
## Abstract ## Purpose: To develop a robust 3D fast spin echo (FSE) T~2~‐weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high‐quality multiplanar reformations. ## Materials and Methods: The Iterative Decomposition of water and fat with Echo Asym
## Abstract ## Purpose: To provide improved blood suppression in three‐dimensional inner‐volume fast spin‐echo (3D IV‐FSE) carotid vessel wall imaging by using a hybrid preparation consisting of double inversion‐recovery (DIR) and diffusion sensitizing gradients (DSG). ## Materials and Methods: