## Abstract The development and introduction of effective treatment for influenza A in the form of neuraminidase inhibitors have made the rapid diagnosis of infection important especially in high‐risk populations. The aim of this study was to develop a real‐time nucleic acid sequenced based amplifi
Real-Time, Sequence-Specific Detection of Nucleic Acids during Strand Displacement Amplification
✍ Scribed by James G. Nadeau; J.Bruce Pitner; C.Preston Linn; James L. Schram; Cheryl H. Dean; Colleen M. Nycz
- Publisher
- Elsevier Science
- Year
- 1999
- Tongue
- English
- Weight
- 140 KB
- Volume
- 276
- Category
- Article
- ISSN
- 0003-2697
No coin nor oath required. For personal study only.
✦ Synopsis
Strand displacement amplification (SDA) is an isothermal nucleic acid amplification method based on the primer-directed nicking activity of a restriction enzyme and the strand displacement activity of an exonuclease-deficient polymerase. Here we describe fluorogenic reporter probes that permit realtime, sequence-specific detection of targets amplified during SDA. The new probes possess the singlestrand half of a BsoBI recognition sequence flanked on opposite sides by a fluorophore and a quencher. The probes also contain target-binding sequences located 3 to the BsoBI site. Fluorophore and quencher are maintained in sufficiently close proximity that fluorescence is quenched in the intact single-stranded probe. If target is present during SDA, the probe is converted into a fully double-stranded form and is cleaved by the restriction enzyme BsoBI, which also serves as the nicking agent for SDA. Fluorophore and quencher diffuse apart upon probe cleavage, causing increased fluorescence. Target replication may thus be followed in real time during the SDA reaction. Probe performance may be enhanced by embedding the fluorogenic BsoBI site within the loop of a folded hairpin structure. The new probe designs permit detection of as few as 10 target copies within 30 min in a closed-tube, real-time format, eliminating the possibility of carry-over contamination. The probes may be used to detect RNA targets in SDA mixtures containing reverse transcriptase. Furthermore, a two-color competitive SDA format permits accurate quantification of target levels from the real-time fluorescence data.
📜 SIMILAR VOLUMES
## Abstract Several real‐time PCR and nucleic acid sequence‐based amplification (NASBA) primer pairs and a modified real‐time PCR primer pair for the detection of enteroviruses were compared. The modified real‐time PCR primer pair was evaluated on clinical samples in comparison with cell culture us