𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Real-time measurement of blood vessel occlusion during microsurgery

✍ Scribed by Christian M. Sauer; Damian H. Tomlin; Homayoun Mozaffari Naeini; Oleg Gerovichev; Nitish V. Thakor


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
498 KB
Volume
7
Category
Article
ISSN
1092-9088

No coin nor oath required. For personal study only.

✦ Synopsis


Measurement and feedback of vascular properties during microsurgery is generally not available. We carried out real-time in vivo measurement and analysis of microsurgical occlusion of 1-2-mm diameter arteries and veins in rodents. A pair of forceps mounted with strain gauges was designed for applying and directly measuring the force on tissue. Forces between 0 and 450 mN were applied, with the device having a resolution of 0.5 mN. We performed in vivo experiments on the rat femoral (n ‫؍‬ 5) and abdominal (n ‫؍‬ 8) blood vessels to measure the elastic restoration force of the tissue in response to radial compression at different levels of force. On average, the minimum occlusion force was 57 mN for the rat artery. During steady application of force, the perturbations in the blood vessel due to heartbeat are visible in the force data. These force oscillations ranged between 1 and 3 mN around the mean steady-state force applied. It was determined that the magnitude of the Fourier spectral peak corresponding to heartbeat frequency can be used as a measure of the patency of the blood vessel, and can provide feedback to microsurgeons to avoid damage to the vessel by application of excess force. Comp Aid Surg 7: 364 -370 (2002).


πŸ“œ SIMILAR VOLUMES


Real-time measurement of skin radiation
✍ Hwang, Edward ;Gaxiola, Efrain ;Vlietstra, Ronald E. ;Brenner, Alan ;Ebersole, D πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 63 KB

A novel skin dose monitor was used to measure radiation incident on maximal X-ray exposed skin during 135 diagnostic and 65 interventional coronary procedures. For the diagnostic studies (n ‫؍‬ 135), mean skin dose was 180 ؎ 64 mGy; for PTCA (n ‫؍‬ 35), it was 1021 ؎ 674 mGy, single stents (n ‫؍‬ 25

Real-time measurements of human chondroc
✍ R. Santoro; O. Braissant; B. MΓΌller; D. Wirz; A.U. Daniels; I. Martin; D. Wendt πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 157 KB

## Abstract Isothermal microcalorimeters (IMC) are highly sensitive instruments that allow the measurement of heat flow in the microwatt range. Due to their detection of minute thermal heat, IMC techniques have been used in numerous biological applications, including the study of fermentation proce

Use of ultrasonic time-domain reflectome
✍ W. F. C. Kools; S. Konagurthu; A. R. Greenberg; L. J. Bond; W. B. Krantz; Th. Va πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 149 KB πŸ‘ 2 views

The dry-cast membrane-formation process is a principal technique by which asymmetric porous membranes as well as dense films can be obtained. Much insight into the fundamental nature of this process can be obtained via real-time measurements of mass and thickness changes. The former requires an equa

Noninvasive blood flow imaging for real-
✍ Yu-Chih Huang; Tyson L. Ringold; J. Stuart Nelson; Bernard Choi πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 236 KB

## Abstract ## Background and Objectives During laser therapy of port wine stain (PWS) birthmarks, regions of persistent perfusion may exist. Immediate retreatment of such regions may improve PWS laser therapeutic outcome. To address this need, we propose use of laser speckle imaging (LSI) to prov

Terahertz in-line sensor for direct coat
✍ Robert K. May; Michael J. Evans; Shuncong Zhong; Ian Warr; Lynn F. Gladden; Yaoc πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 716 KB

We present a new in-line measurement technique to determine the coating thickness of individual pharmaceutical tablets during film coating in a pan coating unit using pulsed terahertz technology. Results of these real-time terahertz measurements acquired during a production scale coating run are val

Estimation of gestational age during the
✍ Luciano Bovicelli; Luigi F. Orsini; Nicola Rizzo; Patrizio Calderoni; Francesco πŸ“‚ Article πŸ“… 1981 πŸ› John Wiley and Sons 🌐 English βš– 882 KB

## Abstract A series of 237 patients in the first trimester of pregnancy were examined to derive normal growth curves for fetal crown‐rump length (CRL) and biparietal diameter (BPD) using sector scanner real‐time ultrasound equipment. Conventional B‐scan CRL measurements were obtained from 50 of th