𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy

✍ Scribed by Riederer, S


Publisher
Springer
Year
1999
Tongue
English
Weight
233 KB
Volume
8
Category
Article
ISSN
0968-5243

No coin nor oath required. For personal study only.

✦ Synopsis


Although a variety of timing techniques and data acquisition strategies have been used for three-dimensional contrast-enhanced MR angiography, many are still limited by inadequate overall reliability, limited spatial resolution, or complexity. A technique is presented in this work in which contrast arrival is detected in the targeted vasculature in real time using MR fluoroscopy. Upon detection the operator triggers a 3D MR angiographic acquisition which uses an elliptical centric view order. It is shown that the view order intrinsically provides a high degree of venous suppression which in turn allows acquisition times of 30 s or longer, permitting high spatial resolution. The reliability of fluoroscopic triggering in bolus detection is shown to be over 90%. The technique provides high quality contrast-enhanced MR angiograms for many vascular regions.


📜 SIMILAR VOLUMES


Embedded MR fluoroscopy: High temporal r
✍ Sean B. Fain; Stephen J. Riederer; John Huston III; Bernard F. King 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 349 KB

## Abstract A method termed “embedded fluoroscopy” for simultaneously acquiring a real‐time sequence of 2D images during acquisition of a 3D image is presented. The 2D images are formed by periodically sampling the central phase encodes of the slab‐select direction during the 3D acquisition. The tr

Semiautomatic segmentation and stenosis
✍ Cornelis M. van Bemmel; Max A. Viergever; Wiro J. Niessen 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 433 KB 👁 1 views

## Abstract A technique is presented for the segmentation and quantification of stenosed internal carotid arteries (ICAs) in 3D contrast‐enhanced MR angiography (CE‐MRA). Segmentation with sub‐pixel accuracy of the ICA is achieved via level‐set techniques in which the central axis serves as the ini

Enhanced mass on contrast-enhanced breas
✍ Hidetake Yabuuchi; Yoshio Matsuo; Takashi Okafuji; Takeshi Kamitani; Hiroyasu So 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 282 KB

## Abstract ## Purpose To evaluate the diagnostic accuracy of a combination of dynamic contrast‐enhanced MR imaging (DCE‐MRI) and diffusion‐weighted MR imaging (DWI) in characterization of enhanced mass on breast MR imaging and to find the strongest discriminators between carcinoma and benignancy.

Dynamic contrast-enhanced breath-hold MR
✍ Russell N. Low; Joel S. Sigeti; S. Y. Thomas Song; Ann Shimakawa; Norbert J. Pel 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 1022 KB

## Abstract The purpose of this paper was to evaluate the use of dynamic gadopentetate dimeglumine‐enhanced, breath‐hold spoiled gradient‐recalled (SPGR) MR imaging with cardiac compensation (CMON) compared to spin‐echo MR imaging in patients with thoracic malignancy. We retrospectively reviewed MR