Real Time Image Rotation Using Dynamic Reconfiguration
✍ Scribed by E. Bourennane; C. Milan; M. Paindavoine; S. Bouchoux
- Publisher
- Elsevier Science
- Year
- 2002
- Tongue
- English
- Weight
- 474 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1077-2014
No coin nor oath required. For personal study only.
✦ Synopsis
Image Rotation Using Dynamic Reconfiguration F ield programmable gate array (FPGA) components are widely used nowdays to implement various algorithms, such as digital filtering, in real time. The emergence of dynamically reconfigurable FPGAs made it possible to reduce the number of necessary resources to carry out an image-processing task (tasks chain). In this article, an image-processing application, image rotation, that exploits the FPGAs dynamic reconfiguration method is presented. This paper shows that the choice of an implementation, static or dynamic reconfiguration, depends on the nature of the application. A comparison is carried out between the dynamic and the static reconfiguration using two criteria: cost and performance. It appears that, according to the nature of the application, the dynamic reconfiguration can be less or more advantageous. In order to be able to test the validity of our approach in terms of algorithm and architecture adequacy, we realized an AT40K40-based board ''ARDOISE''.
📜 SIMILAR VOLUMES
## Real-Time Digital Image Stabilization Using Kalman Filters 1 T his paper presents a novel, real-time stabilization system that uses Kalman filters to remove short-term image fluctuations with retained smooth gross movements. The global camera motion is defined in terms of constant acceleration
## Abstract The ultra‐high‐speed echo‐planar imaging (EPI) method is combined with velocity encoding prior to EPI read‐out, thereby allowing real‐time measurement of flow. Results of EPI flow measurement experiments are presented on phantoms and human volunteers. © 1991 Academic Press. Inc.
## Abstract MR‐guided intravascular interventions require image update rates of up to 10 images per second, which can be achieved using parallel imaging. However, parallel imaging requires many coil elements, which increases reconstruction times and thus compromises real‐time image reconstruction.
This paper proposes an imaging method using ultrasound for objects which cannot be observed optically, such as objects in muddy water or in mist. The acoustic Fourier transform (AFT) is described, whereby the object information is Fourier-transformed using the ultrasound. A transmitter element and a
## Abstract We have developed a new in vivo mouse model to image single cancer‐cell dynamics of metastasis to the lung in real‐time. Regulating airflow volume with a novel endotracheal intubation method enabled controlling lung expansion adequate for imaging of the exposed lung surface. Cancer cell