𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Rapid screening and characterization of drug metabolites using a multiple ion monitoring–dependent MS/MS acquisition method on a hybrid triple quadrupole-linear ion trap mass spectrometer

✍ Scribed by Ming Yao; Li Ma; W. Griffith Humphreys; Mingshe Zhu


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
281 KB
Volume
43
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A novel LC/MS/MS method that uses multiple ion monitoring (MIM) as a survey scan to trigger the acquisition of enhanced product ions (EPI) on a hybrid quadrupole‐linear ion trap mass spectrometer (Q TRAP) was developed for drug metabolite identification. In the MIM experiment, multiple predicted metabolite ions were monitored in both Q1 and Q3. The collision energy in Q2 was set to a low value to minimize fragmentation. Results from analyzing ritonavir metabolites in rat hepatocytes demonstrate that MIM‐EPI was capable of targeting a larger number of metabolites regardless of their fragmentation and retained sensitivity and duty cycle similar to multiple reaction monitoring (MRM)‐EPI. MIM‐based scanning methods were shown to be particularly useful in several applications. First, MIM‐EPI enabled the sensitive detection and MS/MS acquisition of up to 100 predicted metabolites. Second, MIM‐MRM‐EPI was better than MRM‐EPI in the analysis of metabolites that undergo either predictable or unpredictable fragmentation pathways. Finally, a combination of MIM‐EPI and full‐scan MS (EMS), as an alternative to EMS‐EPI, was well suited for routine in vitro metabolite profiling. Overall, MIM‐EPI significantly enhanced the metabolite identification capability of the hybrid triple quadrupole‐linear ion trap LC/MS. Copyright © 2008 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Rapid screening and characterization of
✍ Gérard Hopfgartner; Christophe Husser; Manfred Zell 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 216 KB

## Abstract The application of a new hybrid RF/DC quadrupole–linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several hig

A novel approach to perform metabolite s
✍ Wilson Z. Shou; Lisa Magis; Austin C. Li; Weng Naidong; Matthew S. Bryant 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 243 KB

## Abstract __In vitro__ metabolic stability experiments using microsomes or other liver preparations are important components in the discovery and lead‐optimization stages of compound selection in the pharmaceutical industry. Currently, liquid chromatography–tandem mass spectrometric (LC–MS/MS) su