Impairment of visual perception and visu
✍
G. Beckers; V. Hömberg
📂
Article
📅
1991
🏛
Springer-Verlag
🌐
English
⚖ 1021 KB
Transcranial magnetic stimulation (TMS) of occipital cortex was performed using a magneto-electric stimulator with a maximum output of 2 Tesla in 24 normal volunteers. The identification of trigrams, presented for 14 ms in horizontal or vertical arrays was significantly impaired when the visual stim