Rapid characterization of glycosaminoglycans using a combined approach by infrared and Raman microspectroscopies

✍ Scribed by Nathalie Mainreck; Stéphane Brézillon; Ganesh D. Sockalingum; François-Xavier Maquart; Michel Manfait; Yanusz Wegrowski


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
589 KB
Volume
100
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.

✦ Synopsis


This study describes a complementary infrared (IR) and Raman spectroscopic investigations of a set of biomolecule representatives of glycosaminoglycans (GAGs) class. Both IR and Raman data exhibit characteristic spectral signatures that allow a direct molecular distinction of these compounds. Comparison of these molecular signatures clearly evidences the differences between heparan sulfate and heparin by computing the intensity ratio between the 1248 cm -1 and 1043 cm -1 peaks, corresponding respectively to sulfate and C O C linkages. Identically, chondroitin-4-sulfate and chondroitin-6-sulfate are differentiated via the 730 cm -1 and 853 cm -1 bands (axial orientation) and the 822 cm -1 and 1000 cm -1 bands (equatorial orientation). These orientations concern the sulfate groups of these molecules. Secondly, multivariate statistical methods were employed to analyze the data set. Hierarchical cluster analysis (HCA) of both IR and Raman spectra showed a very good differentiation between the different structures. In addition, the sulfatation degree could be obtained from this classification. Principal component analysis using three principal components (PCs) confirmed the findings of HCA and, furthermore, comparisons of the PC loadings highlight the main molecular differences between the members of this class of biological molecules. It is expected that these microspectroscopic methods will be useful in identifying GAG spectral signatures in complex biological systems.


📜 SIMILAR VOLUMES


The potential for histological screening
✍ Joanne Hutchings; Catherine Kendall; Brian Smith; Neil Shepherd; Hugh Barr; Nich 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 773 KB

## Abstract Rapid Raman mapping was carried out on 20 μm sections of oesophageal biopsy samples. Contiguous 7 μm sections were stained with haematoxylin and eosin (H&E) with histopathology provided by an expert pathologist. The step size and acquisition times were varied and the resulting spectra,

Quantification and Characterization of G
✍ C.H.A. Vandelest; E.M.M. Versteeg; J.H. Veerkamp; T.H. Vankuppevelt 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 627 KB

A rapid, sensitive, and nonradioactive method has been developed for the quantification and characterization of glycosaminoglycans. The method is based on the separation of different types of glycosaminoglycans in agarose gel and subsequent fixation and staining with the cationic dye azure \(A\), fo

Analysis of skin images using texture de
✍ C. Umarani; L. Ganesan; S. Radhakrishnan 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 385 KB

## Abstract In this article, an attempt has been made to analyze various skin (textured) images. They are caused because of hot water, chemical, electrical, thermal, cigarette, etc. These images are analyzed using our texture representation scheme. Our approach uses a set of 92 texture primitives.

Identification of Biotic and Abiotic Par
✍ R. Geßner; C. Winter; P. Rösch; M. Schmitt; R. Petry; W. Kiefer; M. Lankers; J. 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 446 KB 👁 1 views

## Abstract __A highly versatile setup, which introduces an optical gradient trap into a Raman spectrometer, is presented. The particular configuration, which consists of two lasers, makes trapping independent from the Raman excitation laser and allows a separate adjustment of the trapping and exci