Rapid cardiac-output measurement with ungated spiral phase contrast

✍ Scribed by Jong B. Park; Bob S. Hu; Steven M. Conolly; Krishna S. Nayak; Dwight G. Nishimura


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
619 KB
Volume
56
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

An ungated spiral phase‐contrast (USPC) method was used to measure cardiac output (CO) rapidly and conveniently. The USPC method, which was originally designed for small peripheral vessels, was modified to assess CO by measuring flow in the ascending aorta (AA). The modified USPC used a 12‐interleaf spiral trajectory to acquire full‐image data every 283 ms with 2‐mm spatial resolution. The total scan time was 5 s. For comparison, a triggered real‐time (TRT) method was used to indirectly calculate CO by measuring left‐ventricular (LV) volume. The USPC and TRT measurements from all normal volunteers agreed. In a patient with patent ductus arteriosus (PDA), high CO was measured with USPC, which agreed well with the invasive cardiac‐catheterized measurement. In normal volunteers, CO dropped about 20–30% with Valsalva maneuvering, and increased about 100% after exercise. Continuous 28‐s cycling between Valsalva maneuvering and free‐breathing showed that USPC can temporally resolve physiological CO changes. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Rapid measurement of renal artery blood
✍ Jong B. Park; Juan M. Santos; Brian A. Hargreaves; Krishna S. Nayak; Graham Somm 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 525 KB

## Abstract ## Purpose To verify the potential of ungated spiral phase‐contrast (USPC), which has been shown to provide accurate and reproducible time‐averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. ## Materials and Methods The RABF rates

Rapid measurement of time-averaged blood
✍ Jong B. Park; Eric W. Olcott; Dwight G. Nishimura 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 462 KB

## Abstract A novel ungated spiral phase‐contrast (USPC) imaging method was developed for rapid measurement of time‐averaged blood‐flow rates in the presence of pulsatility. The spatial point‐spread function was analyzed to provide an intuitive understanding of how spiral trajectories, which sample

Comparison of cerebral artery blood flow
✍ Dieter R. Enzmann; Michael P. Marks; Norbert J. Pelc 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 912 KB

## Abstract Cine phase‐contrast (PC) magnetic resonance (MR) pulse sequences have been used to measure blood flow in a variety of vessels. Because the cine PC sequence is time‐consuming, this prospective study was undertaken to compare it with an ungated PC technique for measuring average blood flo

Quantitative assessment of cardiac outpu
✍ Hung-Yu Lin; Darren Freed; Trevor W.R. Lee; Rakesh C. Arora; Ayyaz Ali; Waiel Al 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 675 KB

## Abstract ## Purpose: To validate noninvasive cardiac output measurements of phase‐contrast magnetic resonance imaging (PC‐MRI) and cine MRI using an invasive pressure‐volume (PV) loop technique on a swine model. ## Materials and Methods: We compared three methods for evaluating cardiac functi