Solid-phase microextraction combined with fast short-column liquid chromatography/mass spectrometry (SPME/LC/MS) was used for isolating and analysing 11 corticosteroids and 2 steroid conjugates from urine samples. Several SPME parameters such as polarity of fibres, extraction time and effect of ioni
Rapid analysis of tetracycline antibiotics by combined solid phase microextraction/high performance liquid chromatography/mass spectrometry
β Scribed by Chris M. Lock; Luke Chen; Dietrich A. Volmer
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 177 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
The technique of solid phase microextraction (SPME) combined on-line with high performance liquid chromatography/mass spectrometry (HPLC/MS) has been applied to the analysis of seven tetracycline analogues. Rapid baseline separation was achieved in under 5 min using a short 3 microm RP-18e cartridge column. Optimisation of the SPME procedure is described including choice of extracting fibre and modification of the sample by heating or salting out of the analytes. Detection limits of 4-40 ng/mL were obtained for the various analogues from extracted aqueous samples and absolute amounts of analyte extracted by the method determined using external calibration. To demonstrate the applicability of the technique for real samples the extraction of tetracycline from milk is described.
π SIMILAR VOLUMES
9-Fluorenylmethyloxycarbonyl (FMOC) derivatives of catecholamines, including dopamine (DA; 3,4-dihydroxyphenethylamine), norepinephrine (NE; 2-amino-1-(3,4-dihydroxyphenyl)ethanol) and epinephrine (EPI; 1-phenyl-1-hydroxy-2-methylaminopropane) as well as 3, 4-dihydroxybenzylamine (DHBA) have been an
The sensitivity of mass spectrometry combined with the separatory power of high-performance liquid chromatography was used to investigate the venom of individual cone shells. This analysis has revealed that cone venoms contain a complex mixture of peptides which vary quantitatively and qualitatively
The decomposition of erythromycin A (EA) in aqueous solution was examined in the pH range 2-13 by means of combined solid-phase microextraction (SPME) and liquid chromatography/electrospray ionization tandem mass spectrometry. Degradation of EA, especially at lower pH values (pH 3), was very rapid a