𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty

✍ Scribed by Zorzetto, Mario ;Bernardi, Guglielmo ;Morocutti, Giorgio ;Fontanelli, Alessandro


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
34 KB
Volume
40
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


A detailed monitoring, on the basis of single procedures, was undertaken to assess the patient exposure and the occupational doses received by the operators (cardiologist, technician, and nurse) during diagnostic coronary angiography (CAG) and percutaneous transluminal coronary angioplasty (PTCA). The occupational dose to the staff was measured at the collar level using thermoluminescent dosimeters (TLD) to examine the neck and head exposure. Patient exposure was assessed by the dose-area product (DAP in Gy/cm 2 ) and by the skin dose (mGy) at the level of thyroid. The mean neck dose per procedure for cardiologist was about 0.05 mGy, a reasonable level to comply with the International Commission on Radiological Protection (ICRP) eye lens recommended limit. No significant differences were detected between CAG (39 procedures) and PTCA (19 procedures). Relatively high radiation doses are given to the lung of the patient with a significant ICRP lifetime risk of about 10 23 . The patients' mean DAP was 55.9 Gy/cm 2 for CAG (79 procedures) and 91.8 Gy/cm 2 for PTCA (31 procedures) (P F 0.01). About 70% in CAG and 48% in PTCA of the total dose resulted from the cine examination; in PTCA the total mean DAP was about 60% higher than in CAG procedures.


πŸ“œ SIMILAR VOLUMES


Radiation exposure to patients undergoin
✍ Bakalyar, Donovan M. ;Castellani, Mark D. ;Safian, Robert D. πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 77 KB

There has been a recent wave of concern over radiation exposure to patients during cardiac catheterization. Accordingly, we measured the area-exposure product (AEP) to patients undergoing diagnostic and interventional cardiac catheterization procedures. Fluoroscopic and cinefluorographic exposures w

Decreasing operators' radiation exposure
✍ Miles Behan; Peter Haworth; Paul Colley; Michael Brittain; Andrew Hince; Michael πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 384 KB πŸ‘ 1 views

## Abstract Aim: Transradial coronary procedures are associated with decreased vascular access site complications and other benefits compared to the femoral approach. There is some concern however about high‐recorded radiation doses for interventional cardiologists using the transradial route. We t

Combined use of orgaran and reopro durin
✍ Warren J. Cantor; Kori Leblanc; Bernadette Garvey; K. Randal Watson; Al Rasymas; πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 31 KB

Orgaran, a heparinoid, has been used successfully in patients with heparin-induced thrombocytopenia. We report three cases in which Orgaran was combined with the glycoprotein IIb/IIa receptor antagonist Reopro during coronary angioplasty. Orgaran was given as a single intravenous bolus of 1500 anti-