๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

R407C as an alternative to R22 in vapour compression plant: an experimental study

โœ Scribed by Adriana Greco; Rita Mastrullo; Adolfo Palombo


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
296 KB
Volume
21
Category
Article
ISSN
0363-907X

No coin nor oath required. For personal study only.

โœฆ Synopsis


The problem of HCFC22 phase-out in refrigeration plants is analysed. A comparison is performed between R22 and R407C. The latter seems a promising drop-in substitute. Indeed, its use in existing plants would only require discharge of mineral oil and refilling with a compatible polyolester oil. The experimental tests are performed in a plant consisting in a water-cooled vapor-compression circuit employed for cooling a water-glycol mixture in a closed-loop system. Both the thermodynamic properties and general performance of R407C are comparable with those of R22. The COP, however, is 5-17% lower. As a consequence, in order to provide the same refrigerating load, a plant working with R407C requires higher electric-power consumption. The operational behaviour of R407C is increasingly better with increasing condensation and evaporation temperature. Therefore, R407C is a good R22 substitute in all applications requiring high evaporation temperatures, such as air-conditioning plants.


๐Ÿ“œ SIMILAR VOLUMES


R407c as an alternative to R22 in refrig
โœ B. Mongey; N. J. Hewitt; J. T. McMullan ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 573 KB

A refrigeration test facility was constructed to examine the performance of potential alternatives to R22. For the purpose of this paper, the performance of R407c (a zeotropic mixture of R134a, R125 and R32 in a 52% 25% 23% composition by mass) was compared to that of R22. It was found that the perf

Thermodynamic analysis of R422 series re
โœ Akhilesh Arora; H. L. Sachdev ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 232 KB ๐Ÿ‘ 1 views

In the present study, the first and second law analysis of R422 series refrigerants (R422A, R422B, R422C and R422D) is presented as an alternative to HCFC22. A computational model, developed in engineering equation solver software, is employed for comparing the performance of these refrigerants in v

Use of rainbow trout primary epidermal c
โœ Kevin Dowling; Carmel Mothersill ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 170 KB ๐Ÿ‘ 1 views

Increased concern has centered around environmental contaminants that exert estrogenic effects. A class of nonionic surfactants, the nonylphenol ethoxylates (such as the compound nonoxynol), are an example of one such group of contaminants. We studied the effects of nonoxynol (โฃ-(4-nonylphenyl)--hyd