We have studied the laser performance of Nd : KGW and Nd : YAG rods by monitoring the 1.06 pm laser emission at 78.5 K and 300 K. Our observations indicate that the laser efficiency from Nd : KGW is much higher than from Nd : YAG at these two temperatures. The laser threshold in Nd: KGW is lower at 78.5 K than at 300 K but it is always lower than that in Nd : YAG.
π SIMILAR VOLUMES
We report for the first time (to our knowledge) a diode-pumped Nd:SGG laser emitting at 1070 nm. A power of 1.23 W at 1070 nm has been achieved in continuouswave (CW) operation with a fiber-coupled laser diode emitting 18.2 W at 806 nm. Intracavity second-harmonic generation (SHG) in CW mode has als
Efficient and compact blue laser output at 468 nm is generated by intracavity frequency doubling of a continuouswave (CW) diode-pumped Nd:CNGG laser at 935 nm. With 17.8 W of diode pump power and the frequency-doubling crystal BiB3O6 (BiBO), a maximum output power of 490 mW in the blue spectral rang