Near-infrared spectroscopy (NIRS) is a novel method for the measurement of tissue oxygenation and may have a role in monitoring liver oxygenation and viability. The aim of this study is to validate the application of NIRS for monitoring hepatic tissue oxygenation. Large Landrace pigs (n โซุโฌ 12) unde
Quantitative detection of hemoglobin saturation in the liver with near-infrared spectroscopy
โ Scribed by Toshiyuki Kitai; Akira Tanaka; Atsuo Tokuka; Koichi Tanaka; Yoshio Yamaoka; Kazue Ozawa; Konomu Hirao
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 906 KB
- Volume
- 18
- Category
- Article
- ISSN
- 0270-9139
No coin nor oath required. For personal study only.
โฆ Synopsis
To quantify the changes in oxygen saturation of hemoglobin in the liver in hypoxia and liver transplantation, we applied a novel method using near-infrared spectroscopy. Instead of the conventional two-wavelength method, we obtained near-infrared data from a wide spectral range of 700 nm to 1,000 nm with continuous-wave spectroscopy. To correct the flattened spectral shape caused by photon scattering in living tissue, we then applied an equation taking into account the relationship between absorber concentration and actual absorption in scattering materials as assessed with time-resolved spectroscopy. Hepatic hemoglobin oxygen saturation was calculated with multicomponent analysis. In room air, hepatic hemoglobin oxygen saturation of rabbit was calculated as 57.4% & 2.5% (mean +-S.E.M., n = 7). Arterial, portal and hepatic venous hemoglobin oxygen saturation were simultaneously measured as 97.5% -C 0.7%, 77.1% 2 3.4% and 55.5% 2 4.6%, respectively. The changes in hepatic hemoglobin oxygen saturation seen in graded hypoxia were also close to those in hepatic venous hemoglobin oxygen saturation, suggesting that the average oxygenation state of sinusoidal blood approximates that in the central vein. We tested the clinical applicability of this method in a case of liver transplantation. It was determined that the hepatic hemoglobin oxygen saturation of the graft liver was heterogeneously distributed and that the initially low level of hepatic hemoglobin oxygen saturation was increased by the ligation of portal-systemic shunts.
๐ SIMILAR VOLUMES
Quantification analysis with near-infrared (NIR) spectroscopy typically requires utilizing chemometric techniques, such as partial least squares (PLS) method, to achieve the desired selectivity. This article points out a major limitation of these statistical-based calibration methods. The limitation
A new method for analyses of a commercial pharmaceutical formulation based on near infrared diffuse reflectance spectroscopy (NIRRS) with fibre optical probe and using partial least-squares regression (PLS) for multivariate calibration is proposed. Analyses include the determination of the active co
Split liver transplantation and living donor liver transplantation (LDLT) commonly use a right liver graft without the middle hepatic vein (MHV). Although tributaries of the MHV are not reconstructed in the majority of cases, the alterations of the microcirculation and its regional functions remain