𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantitative analysis of six pesticides in fruits by capillary electrophoresis-electrospray-mass spectrometry

✍ Scribed by Ana Juan-García; Guillermina Font; Yolanda Picó


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
423 KB
Volume
26
Category
Article
ISSN
0173-0835

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A method to identify and quantify six pesticide residues – dinoseb, pirimicarb, procymidone, pyrifenox, pyrimethanil, and thiabendazole – in peaches and nectarines using capillary electrophoresis‐electrospray ionization‐quadrupole ion trap‐tandem mass spectrometry (CE‐ESI‐MS/MS) is described. Separation was carried out using a buffer of 0.3 M ammonium acetate at pH 4 with 10% methanol. Pesticide residues present in peach and nectarine samples were preconcentrated by solid‐phase extraction using C~18~, eluted with CH~2~Cl~2~, concentrated to dryness, and redissolved in buffer to obtain lower detection limits. The recoveries of the analytes ranged from 58 to 99% and the relative standard deviations were 9 to 19%. Under optimized CE‐MS/MS conditions the minimum detectable levels for the six pesticides in spiked peach samples were between 0.01 mg/kg for pirimicarb and 0.05 mg/kg for procymidone with pressure injection of 50 mbar for 5 s (5 nL) at a signal‐to‐noise ratio of 3, which constitutes a severalfold increase in sensitivity compared to CE‐MS, using a single quadrupole, and to conventional CE‐UV. The potential of the method was demonstrated by analyzing different samples taken from regional agricultural cooperatives. The pesticides most often detected were thiabendazole and procymidone.


📜 SIMILAR VOLUMES


Capillary electrophoresis-electrospray-m
✍ Miguel Herrero; Elena Ibañez; Alejandro Cifuentes 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 376 KB 👁 1 views

## Abstract In the present work, an exhaustive review of the main developments and applications of CE‐MS for peptide analysis is given. This review includes the use of different CE separation modes, MS analyzers, capillary coatings, preconcentration techniques, on‐chip applications as well as other

Analyses of phenolic compounds by capill
✍ Fernando Lafont; María A. Aramendia; Isabel García; Víctor Borau; César Jiménez; 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 68 KB 👁 2 views

Several phenolic compounds found in olive mill wastewater were quantitatively and qualitatively analyzed on an uncoated fused-silica capillary electrophoresis column (67 cm  75 mm i.d.) using 30 mM aqueous ammonium acetate buffer/methanol (90:10) and negative electrospray mass spectrometry detectio