𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantitation of human cytomegalovirus in recipients of solid organ transplants by real-time quantitative PCR and pp65 antigenemia

✍ Scribed by Catherine Mengelle; Christophe Pasquier; Lionel Rostaing; Karine Sandres-Sauné; Jacqueline Puel; Laetitia Berges; Laurence Righi; Christiane Bouquies; Jacques Izopet


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
106 KB
Volume
69
Category
Article
ISSN
0146-6615

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Human cytomegalovirus (HCMV) infections and anti‐HCMV treatment are usually monitored by measuring pp65 antigenemia. This method is time‐consuming, labour‐intensive and requires skilled operators. We have compared results obtained using real‐time Light Cycler™ quantitative PCR (QPCR) and the pp65 antigen assay on serial samples collected from recipients of solid organ transplants. We collected 198 blood samples from 14 solid organ transplant recipients and assayed them for pp65 antigen and with Light Cycler™ PCR. HCMV DNA was extracted from leukocytes and measured using primers and probe located in the UL83 region. The quantity of HCMV DNA was calculated using a standard curve prepared from a plasmid containing the target sequence. There was a good correlation between the number of pp65‐positive cells and the DNA copy number (r = 0.57, P < 0.0001). A clinical threshold of 50 positive polymorphonuclear leukocytes/200,000 cells was equivalent to two log~10~ genome copies per capillary by Light Cycler™ PCR. HCMV DNA was detected before pp65 antigen in three patients at a mean time of 10 days, whereas the two tests were positive simultaneously for eight patients. Both the pp65 antigen data and DNA copy number decreased over time during antiviral treatment, although the QPCR was positive 28.2 days after the pp65 antigen assay had become negative. The real‐time Light Cycler™ quantitative PCR assay is a rapid and labour‐saving technique. This molecular method could be useful for monitoring infections and antiviral treatment in recipients of solid organ transplants. J. Med. Virol. 69:225–231, 2003. © 2003 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Assessment of CMV load in solid organ tr
✍ Carlo Mengoli; Riccardo Cusinato; Maria A. Biasolo; Simone Cesaro; Cristina Paro 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 152 KB

## Abstract After bone marrow (BM) or solid‐organ (SO) transplantation viremic __Cytomegalovirus__ (CMV) infection is observed frequently. Quantitative assay of CMV in blood helps the management of this clinical condition. In the present report, 83 samples from 39 solid organ recipients, three CMV

Quantitation of cytomegalovirus DNA by r
✍ Tiziano Allice; Marco Enrietto; Fabrizia Pittaluga; Silvia Varetto; Alessandro F 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 179 KB

The polymerase chain reaction (PCR) for cytomegalovirus (CMV) DNA quantitation provides sensitive and specific data for detecting CMV as well as monitoring the infection and determining the appropriate antiviral strategy. A recently introduced real-time PCR assay for CMV DNA quantitation was applied

Quantitation of cytomegalovirus (CMV) DN
✍ Karine Gourlain; Dominique Salmon; Elyanne Gault; Catherine Leport; Christine Ka 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 89 KB

## Abstract In HIV‐infected patients treated with highly active antiretroviral therapy (HAART) included in the Predivir cohort, we have evaluated the usefulness of CMV DNA quantitation by a TaqMan^®^ PCR assay from peripheral blood leukocytes (PBLs) to predict CMV disease occurrence. In parallel wi

Quantitation of replication of the HCV g
✍ Lan Lin; Louis Libbrecht; Jannick Verbeeck; Chris Verslype; Tania Roskams; Jos v 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 170 KB

## Abstract HCV replicates in liver via an intermediate negative strand RNA. To study the relevance of HCV genome replication, quantitative strand‐specific HCV real‐time RT‐PCR assays were developed and applied to livers explanted because of end‐stage cirrhosis. The assays have broad ranges of dete