## Abstract Real‐time quantitative polymerase chain reaction (PCR) on the LightCycler instrument (LC‐PCR) was developed to measure the Epstein‐Barr virus (EBV) load in clinical samples. LC‐PCR detected two copies of the EBV genome per 500 ng of DNA. Its specificity was confirmed by assays in EBV‐ne
Quantitation of Epstein–Barr virus mRNA using reverse transcription and real-time PCR
✍ Scribed by Birgit Weinberger; Annelie Plentz; Klaus M. Weinberger; Joachim Hahn; Ernst Holler; Wolfgang Jilg
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 213 KB
- Volume
- 74
- Category
- Article
- ISSN
- 0146-6615
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Monitoring of Epstein–Barr virus (EBV) infection and reactivation in immunocompromized patients (e.g., after organ or bone‐marrow transplantation) is based mainly on serological assays and detection of viral DNA. For further characterization of virus reactivation and monitoring of viral transcription we established real‐time RT‐PCR assays using TaqMan technology to sensitively quantify viral transcripts expressed at different times of the lytic cycle: for BZLF1, an immediate early transactivator initiating the transition from latency to lytic replication, for the DNA‐polymerase BALF5 and for the major viral glycoprotein gp350/220 (BLLF1). RNA‐isolation was optimized to eliminate contaminating DNA. Preparations were shown to be virtually DNA‐free for up to 10^6^ copies of RNA. With our PCR systems, it is possible to detect 10 copies of DNA or 100 copies of RNA per reaction as shown with serial dilutions of DNA‐plasmids or in vitro transcribed RNA, respectively. This corresponds to a detection limit of 8 × 10^2^ copies/10^6^ peripheral blood mononuclear cells (PBMCs). Evaluation of this system showed that even in healthy carriers borderline levels of BLLF1 mRNA were sometimes detectable. In patients with acute infectious mononucleosis (IM) viral transcripts were regularly found in varying concentrations. Extremely high levels of all three mRNA species could be seen in a patient after bone‐marrow transplantation monitored during an episode of lymphoproliferation which regressed during treatment with acyclovir and transfusion of donor T‐cells. This sensitive and reproducible method to detect and quantify different transcripts of EBV can be used to closely monitor reactivation of EBV, e.g., in immunocompromized patients. J. Med. Virol. 74:612–618, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Epstein‐Barr virus (EBV) reactivation is more likely to occur in immunocompromised patients with subsequent higher susceptibility to EBV‐associated lymphoproliferations. In contrast to transplant recipients, limited data are available concerning the EBV load in HIV‐infected patients, wi
## Abstract Human noroviruses (NoV) are the leading cause of epidemic acute gastroenteritis. In order to fully characterize features such as persistence and infectious dose, precise quantification of virus concentration is necessary. The purpose of this study was to compare two methods [endpoint ti
Severe acute respiratory syndrome (SARS) exhibits a high mortality rate and the potential for rapid epidemic spread. Additionally, it has a poorly defined clinical presentation, and no known treatment or prevention methods. Collectively, these factors underscore the need for early diagnosis. Molecul
## Abstract A sensitive and reproducible real‐time PCR assay based on TaqMan technology was developed for the detection and quantitation of hepatitis B virus (HBV) DNA in serum, and compared with an “in‐house” qualitative PCR assay. HBV DNA was measured in 125 serum samples from 76 hepatitis B pati
Reverse transcription-polymerase chain reaction (RT-PCR) 2 is a sensitive technique for analysis of mRNA expression (1, 2). Though mainly used for qual-1