✦ Synopsis


Abstract

Pulsed arterial spin labeling (ASL) techniques have been theoretically and experimentally validated for cerebral blood flow (CBF) quantification. In this study ASL‐FAIRER was used to measure regional pulmonary blood flow (rPBF) in seven healthy subjects. Two general ASL strategies were investigated: 1) a single‐subtraction approach using one tag‐control pair acquisition at an inversion time (TI) matched to the RR‐interval, and 2) a multiple‐subtraction approach using tag‐control pairs acquired at various TIs. The mean rPBF averaged 1.70 ± 0.38 ml/min/ml when measured with the multiple‐subtraction approach, and was approximately 2% less when measured with the single‐subtraction method (1.66 ± 0.24 ml/min/ml). Assuming an average lung density of 0.33 g/ml, this translates into a regional perfusion of approximately 5.5 ml/g/min, which is comparable to other measures of pulmonary perfusion. As with other ASL applications, a key problem with quantitative interpretation of the results is the physical gap between the tagging region and imaged slice. Because of the high pulsatility of PBF, ASL acquisition and data analysis differ significantly between the lung and the brain. The advantages and drawbacks of the single‐ vs. multiple‐subtraction approaches are considered within a theoretical framework tailored to PBF. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Gas exchange and regional redistribution
✍ J.Y. Tsang; M. Middaugh; M. Emery; M.P. Hlastala 📂 Article 📅 1992 🏛 Elsevier 🌐 English ⚖ 661 KB

Acute pulmonary embolism (PE) was induced by injecting polystyrene beads into the right atrium of 18 anaesthetized dogs. The animals were resuscitated for 45 min with either Ringer's Lactate (RL), norepinephrine (NE) or isoproterenol (IP). The multiple inert gas elimination technique (MIGET) was use

Assessment of myocardial blood flow (MBF
✍ Zungho Zun; Eric C. Wong; Krishna S. Nayak 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 536 KB

## Abstract Arterial spin labeling (ASL) is a powerful tool for the quantitative measurement of tissue blood flow, and has been extensively applied to the brain, lungs, and kidneys. ASL has been recently applied to myocardial blood flow (MBF) measurement in small animals; however, its use in humans