𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantification of hepatic steatosis with MRI: The effects of accurate fat spectral modeling

✍ Scribed by Scott B. Reeder; Philip M. Robson; Huanzhou Yu; Ann Shimakawa; Catherine DG Hines; Charles A. McKenzie; Jean H. Brittain


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
376 KB
Volume
29
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To develop a chemical‐shift–based imaging method for fat quantification that accounts for the complex spectrum of fat, and to compare this method with MR spectroscopy (MRS). Quantitative noninvasive biomarkers of hepatic steatosis are urgently needed for the diagnosis and management of nonalcoholic fatty liver disease (NAFLD).

Materials and Methods

Hepatic steatosis was measured with “fat‐fraction” images in 31 patients using a multiecho chemical‐shift–based water‐fat separation method at 1.5T. Fat‐fraction images were reconstructed using a conventional signal model that considers fat as a single peak at –210 Hz relative to water (“single peak” reconstruction). Fat‐fraction images were also reconstructed from the same source images using two methods that account for the complex spectrum of fat; precalibrated and self‐calibrated “multipeak” reconstruction. Single‐voxel MRS that was coregistered with imaging was performed for comparison.

Results

Imaging and MRS demonstrated excellent correlation with single peak reconstruction (r^2^ = 0.91), precalibrated multipeak reconstruction (r^2^ = 0.94), and self‐calibrated multipeak reconstruction (r^2^ = 0.91). However, precalibrated multipeak reconstruction demonstrated the best agreement with MRS, with a slope statistically equivalent to 1 (0.96 ± 0.04; P = 0.4), compared to self‐calibrated multipeak reconstruction (0.83 ± 0.05, P = 0.001) and single‐peak reconstruction (0.67 ± 0.04, P < 0.001).

Conclusion

Accurate spectral modeling is necessary for accurate quantification of hepatic steatosis with MRI. J. Magn. Reson. Imaging 2009;29:1332–1339. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


T1 independent, T2* corrected MRI with a
✍ Catherine D.G. Hines; Huanzhou Yu; Ann Shimakawa; Charles A. McKenzie; Jean H. B 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 581 KB

## Abstract ## Purpose: To validate a T~1~‐independent, T~2~\*‐corrected fat quantification technique that uses accurate spectral modeling of fat using a homogeneous fat‐water‐SPIO phantom over physiologically expected ranges of fat percentage and T~2~\* decay in the presence of iron overload. ##

T1 independent, T2* corrected chemical s
✍ Catherine D.G. Hines; Alex Frydrychowicz; Gavin Hamilton; Dana L. Tudorascu; Kar 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 531 KB

## Abstract ## Purpose: To determine the precision and accuracy of hepatic fat‐fraction measured with a chemical shift‐based MRI fat‐water separation method, using single‐voxel MR spectroscopy (MRS) as a reference standard. ## Materials and Methods: In 42 patients, two repeated measurements were

Hepatic fat quantification using chemica
✍ Seung Soo Lee; Youngjoo Lee; Namkug Kim; Seong Who Kim; Jae Ho Byun; Seong Ho Pa 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 564 KB

## Abstract ## Purpose: To compare the accuracy of four chemical shift magnetic resonance imaging (MRI) (CS‐MRI) analysis methods and MR spectroscopy (MRS) with and without T2‐correction in fat quantification in the presence of excess iron. ## Materials and Methods: CS‐MRI with six opposed‐ and