This study sought to quantify bone ingrowth from a single bone-implant surface into porous block hydroxyapatite used in maxillofacial applications. Seventeen maxillary hydroxyapatite implants (implant time of 4-138 months, 39-month mean) were harvested for analysis from 14 patients. The implants had
Quantification of bone ingrowth within bone-derived porous hydroxyapatite implants of varying density
โ Scribed by K. A. Hing; S. M. Best; K. E. Tanner; W. Bonfield; P. A. Revell
- Book ID
- 110269681
- Publisher
- Springer
- Year
- 1999
- Tongue
- English
- Weight
- 223 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0957-4530
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
## Abstract Previous investigations have shown that both the early biological response and the mechanical properties of a porous hydroxyapatite bone graft substitute are highly sensitive to its pore structure. The objective of this study was to evaluate whether the pore structure continued to influ