We report on the possibility of Q-switching a continuously pumped CO 2 laser using a scanning Michelson interferometer as an end mirror, instead of the habitual well-known strategies. This method, in addition to its simplicity, produces free tail relaxation pulses having duration of about 1.3 ls, wh
Q-switched operation with Fox-Smith-Michelson laser cavity
โ Scribed by X. Huang; L. Huang; M. Gong
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 106 KB
- Volume
- 5
- Category
- Article
- ISSN
- 1612-2011
No coin nor oath required. For personal study only.
โฆ Synopsis
A new kind of three-mirror composite cavity, Fox-Smith-Michelson cavity has been configured. This laser cavity is capable of high power output, owing to the low threshold of Michelson cavity. Also, thanks to the mode selection function of Fox-Smith cavity, stable pulses at high repetition rate can be generated. In our experiment, 15.54 W CW output at 1064 nm has been achieved, with an optic-to-optic conversion efficiency of 42.2%. At the Q-switching repetition rate of 100 kHz, the average output power is 11.92 W, with an optic-to-optic conversion efficiency of 38.2%. For Q-switching frequency from 30 kHz to 100 kHz, the pulse width variation is below 4.4% and the amplitude variation is below 4.8%.