## Abstract Numerous approaches to super‐resolution (SR) of sequentially observed images (image sequence) of low resolution (LR) have been presented in the past two decades. However, neural network methods are almost ignored for solving SR problems. This is because the SR problem traditionally has
Pyramid-based super-resolution of the undersampled and subpixel shifted image sequence
✍ Scribed by Yao Lu; Minoru Imamura
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 449 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0899-9457
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The existing methods for the reconstruction of a super‐resolution image from the undersampled and subpixel shifted image sequence have to solve a large ill‐condition equation group by approximately finding the inverse matrix or performing many iterations to approach the solution. The former leads to a big burden of computation, and the latter causes the artifacts or noise to be overstressed. So they are rarely implemented in practical use. In order to solve these problems, in this article, we consider applying pyramid structure to the super‐resolution of the image sequence and present a suitable pyramid framework, called Super‐Resolution Image Pyramid (SRIP), and determine the pyramid back‐projection. Pyramid structure and methods are widely used in image processing and computer vision. But we have not found their applications to the super‐resolution in literatures. We give a complete description for SRIP. As an example, the Iterative Back‐Projection (IBP) suggested by Peleg (1991, 1993) is integrated in this pyramid framework. The experiments and the error analysis are performed to show the effectiveness of this framework. The image resolution can be improved better even in the case of severely undersampled images. In addition, the other general super‐resolution methods can be easily integrated in this framework so that they can be done in parallel so as to meet the need of real‐time processing. © 2003 Wiley Periodicals, Inc. Int J Imaging Syst Technol 12, 254–263, 2002; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/ima.10033
📜 SIMILAR VOLUMES
## Abstract The original article to which this Erratum refers was published in International Journal of Imaging Systems and Technology (2002) 12(6) 254–263 An error was made in the spelling of the second author's name for the online version of the above article. Please note the correct spelling sh