## Abstract Twenty consecutive cancer patients with a solitary hepatic metastasis detected with dynamic contrast‐material—enhanced computed tomography (CT) who were considered for hepatic resection underwent magnetic resonance (MR) imaging within 18 days after CT. Histologic confirmation was obtain
Pyogenic hepatic abscesses: MRI findings on T1- and T2-weighted and serial gadolinium-enhanced gradient-echo images
✍ Scribed by N. Cem Balci; Richard C. Semelka; Tara C. Noone; Evan S. Siegelman; Bart Op de Beeck; Jeffrey J. Brown; Moon-Gyu Lee
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 333 KB
- Volume
- 9
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To investigate the fate of hyperintense hepatic nodules on nonenhanced T1‐weighted (T1w) gradient‐echo (GRE) magnetic resonance (MR) images in cirrhotic patients. ## Materials and Methods A total of 79 cirrhotic patients with hyperintense nodules (>5 mm) on precontrast opp
## Abstract ## Purpose To compare 3.0T and 1.5T MR systems in terms of the effect of superparamagnetic iron oxide (SPIO) on tumor‐to‐liver contrast in T2\*‐weighted gradient‐echo MRI. ## Materials and Methods SPIO‐enhanced gradient‐echo MR images of the liver with four different TEs (3, 5.3, 6.5
Purpose: To investigate the correlation between the peripheral hyperintense pattern of breast carcinoma on T2weighted images (T2WI) and the early peripheral enhancement (EPE) on dynamic magnetic resonance imaging (MRI) and to examine the histological characteristics involved in the causes thereof.
## Abstract ## Purpose To compare respiratory‐triggered T2‐weighted fast spin‐echo (RTT2W‐FSE) and gradient T2\*‐weighted recalled‐echo (T2\*W‐GRE) images for visualization of malignant hepatic tumors using ferucarbotran‐enhanced magnetic resonance (MR) imaging. ## Materials and Methods Ferucarb
## Abstract ## Purpose: To evaluate the impact of motion on T1 values acquired by using either inversion‐recovery fast spin echo (IR‐FSE) or three‐dimensional (3D) spoiled gradient recalled‐echo (SPGR) sequences for delayed gadolinium‐enhanced magnetic resonance imaging of cartilage (dGEMRIC) in v