𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Pulse subtraction Doppler

✍ Scribed by Veronique Mahue; Jean Martial Mari; Robert J. Eckersley; Colin G. Caro; Meng-Xing Tang


Publisher
Elsevier
Year
2010
Tongue
English
Weight
254 KB
Volume
3
Category
Article
ISSN
1875-3892

No coin nor oath required. For personal study only.

✦ Synopsis


Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation.


πŸ“œ SIMILAR VOLUMES


Doppler invariant pulse compressors
✍ Dov Hazony; Yehonathan Hazony πŸ“‚ Article πŸ“… 1980 πŸ› Elsevier Science 🌐 English βš– 630 KB

A puke compressor is utilized in many aspects of signal processing. Compression is usually accomplished by using special matched-filter-signal pairs. An alternative method takes advantage of the fact that any linear dynamic system can be excited to produce a time-limited output. Accordingly for a gi

Probing tornadoes with a pulse doppler r
✍ D. S. Zrnic; R. J. Doviak; D. W. Burgess; Mr Rodger A. Brown πŸ“‚ Article πŸ“… 1977 πŸ› John Wiley and Sons 🌐 English βš– 782 KB

## Abstract Maximum tornado wind speeds and their radii are deduced by least square fitting of the vortex model velocity spectra to those measured with a pulse Doppler radar. Spectra are analysed from the Stillwater, Oklahoma, 13 June 1975, tornado. Simulated spectra are fitted to those measured fo

Detection of aortic insufficiency by pul
✍ Jonathan M. Ward; Donald W. Baker; Simeon A. Rubenstein; Steve L. Johnson πŸ“‚ Article πŸ“… 1977 πŸ› John Wiley and Sons 🌐 English βš– 602 KB

## Abstract Sixty‐five patients were studied for the presence of aortic insufficiency by auscultation, conventional M mode echocardiography (echo), range‐gated pulse Doppler flowmeter (Doppler), and supravalvular aortic angiography. Aortic insufficiency was demonstrated angiographically in 49 patie

Duplex pulsed Doppler echocardiography i
✍ David G. Meyers; David McCall; Thomas D. Sears; Terry S. Olson; Gary L. Felix πŸ“‚ Article πŸ“… 1986 πŸ› John Wiley and Sons 🌐 English βš– 505 KB

The accuracy of duplex pulsed Doppler echocardiography (d-PDE) for detecting mitral regurgitation was evaluated in 35 patients undergoing d-PDE, cardiac auscultation, and left ventriculography . With three transducer positions, the overall d-PDE sensitivity was 958, specificity was loo%, positive pr