𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Protection of seismic structures using semi-active friction TMD

✍ Scribed by Chi-Chang Lin; Ging-Long Lin; Jer-Fu Wang


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
361 KB
Volume
39
Category
Article
ISSN
0098-8847

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Predictive control of seismic structures
✍ Lyan-Ywan Lu πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 269 KB

## Abstract In this paper a predictive control method especially suitable for the control of semi‐active friction dampers is proposed. By keeping the adjustable slip force of a semi‐active friction damper slightly lower than the critical friction force, the method allows the damper to remain in its

SEMI-ACTIVE TUNED MASS DAMPERS FOR SEISM
✍ ABΓ‰, M. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 446 KB πŸ‘ 2 views

A semi-active tuned mass damper (TMD) which is capable of adjusting initial displacement and damping is applied to seismic protection of structures. Control algorithms are derived in closed forms using perturbation analysis on modal properties of the sinigle degree of freedom (SDOF) structure/TMD sy

ACTIVE AND SEMI-ACTIVE CONTROL OF STRUCT
✍ SINGH, M. P.; MATHEU, E. E.; SUAREZ, L. E. πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 440 KB πŸ‘ 2 views

Considerable effort has been devoted to develop passive and active methods for reducing structural response under seismic excitations. Passive control approaches have already found application in practice. Active control methods, on the other hand, are being vigorously examined for application to ci

Fuzzy logic control of bridge structures
✍ Symans, Michael D.; Kelly, Steven W. πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 483 KB πŸ‘ 3 views

Passive supplemental damping in a seismically isolated structure provides the necessary energy dissipation to limit the isolation system displacement. However, damper forces can become quite large as the passive damping level is increased, resulting in the requirement to transfer large forces at the

CONTROL OF BUILDING SEISMIC RESPONSE BY
✍ C.W. STAMMERS; T. SIRETEANU πŸ“‚ Article πŸ“… 2000 πŸ› Elsevier Science 🌐 English βš– 236 KB

A study has been made of the use of three semi-active friction devices, herein referred to as dampers, to control the seismic response of a building modelled as three masses. With a pseudo-random earthquake input, peak lateral accelerations, inter-storey drift and base displacement relative to groun

VIBRATION CONTROL OF MACHINES BY USE OF
✍ C.W. Stammers; T. Sireteanu πŸ“‚ Article πŸ“… 1998 πŸ› Elsevier Science 🌐 English βš– 222 KB

A semi-active device for the vibration control of machinery foundations or for ride control of vehicles is proposed. A semi-active damper utilising dry friction is employed, with balance logic, a class of sequential damping, being used to minimise the force transmitted. The friction force applied to