✦ Synopsis


Abstract

Purpose

To investigate the T2 decay in prostate tissue for multiexponentiality and to assess how the biexponential model relates to established T2W contrast.

Materials and Methods

A 32‐echo spin‐echo sequence was performed on 16 volunteers. Six single‐voxel decay curves were sampled from each prostate. Prediction accuracies were assessed by jackknifing for the mono‐, bi‐, and triexponential models. The differences were evaluated by cross‐validated analysis of variance (CVANOVA). Multiple linear regression was performed to assess the relation between parameters in the biexponential model and the contrast in T2W images.

Results

Mono‐, bi‐, and triexponential models were preferred in 8 (10%), 72 (86%), and 4 (5%) cases, respectively. The biexponential short T2 was 64 msec (range 43 to 92 msec) and the long T2 was 490 msec (range 161 to 1319 msec). The fitted signal fraction, f, of the long T2 component was 27% (range 3% to 80%). The adjusted R^2^ was 75.1% for the full regression model and decreased by 0.9%, 1.3%, and 39.2% when short T2, long T2, and f were removed from the model, respectively.

Conclusion

Prostatic T2 decay was, in general, biexponential. The differences between the T2 components were large enough for accurate quantification. The T2W image contrast was primarily predicted by the biexponential signal fractions. J. Magn. Reson. Imaging 2008;28:1166–1172. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Sequence design for magnetic resonance s
✍ Charles H. Cunningham; Daniel B. Vigneron; Malgorzata Marjanska; Albert P. Chen; 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 308 KB

## Abstract Magnetic resonance spectroscopic imaging (MRSI) has proven to be a powerful tool for the metabolic characterization of prostate cancer in patients before and following therapy. The metabolites that are of particular interest are citrate and choline because an increased choline‐to‐citrat

Clinical prostate T2 quantification usin
✍ Warren D. Foltz; Supriya Chopra; Peter Chung; Andrew Bayley; Charles Catton; Dav 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 407 KB

## Abstract T~2~ quantification may augment diagnostic T~2~‐weighted imaging; to improve cancer detection via auto‐segmentation of multi‐parametric acquisitions and to potentiate longitudinal studies of prostate cancer. However, robust quantitative techniques are not generally accessible or refined

In vivo magnetic resonance spectroscopy
✍ Gary P. Liney; Lindsay W. Turnbull; Adrian J. Knowles 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 413 KB 👁 2 views

The quantitation of in vivo 1 H MR spectroscopy and dynamic contrast enhanced MR imaging is described for patients with histologically confirmed prostate adenocarcinoma and benign prostatic hypertrophy (BPH). Results are presented which suggest that combined use of these techniques may be helpful in

Depicting adoptive immunotherapy for pro
✍ Reinhard Meier; Daniel Golovko; Sidhartha Tavri; Tobias D. Henning; Christiane K 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 466 KB

## Abstract Genetically modified natural killer (NK) cells that recognize tumor‐associated surface antigens have recently shown promise as a novel approach for cancer immunotherapy. To determine NK cell therapy response early, a real‐time, noninvasive method to quantify NK cell homing to the tumor

Magnetic resonance imaging assessment of
✍ Anil M. Shetty; R. Jason Stafford; Andrew M. Elliott; Wassim Kassouf; Gordon A. 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 377 KB

## Abstract ## Purpose To quantitatively investigate the feasibility of MRI as a tool for assessing the spatial distribution of a convectively delivered agent using a canine prostate model. ## Materials and Methods Canine prostates (ex vivo, __n__ = 3; in vivo, __n__ = 12) were injected under se

Comparison of transrectal ultrasound pro
✍ Tewari, Ashutosh; Indudhara, Ramaiah; Shinohara, Katsuto; Schalow, Erica; Woods, 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 615 KB

There are relatively few reports in the literature comparing transrectal ultrasound (TRUS) to magnetic resonance imaging (MRI) in estimating the volume of the prostate in the management of benign prostatic hyperplasia (BPH). In this study, we compared volumes determined by TRUS with MRI and TRUS-est