An amperometric microsensor for hemoglobin (HB) has been constructed using a carbon fiber electrode modified with poly-,&aminoanthraquinone (pAAQ). Scanning electron microscopic studies showed that the potential range and time of electrochemical polymerization had strong effects on the morphology of
Properties of carbon fibre microelectrodes as a basis for enzyme biosensors
β Scribed by L.I. Netchiporouk; A.A. Shul'ga; N. Jaffrezic-Renault; C. Martelet; R. Olier; R. Cespuglio
- Publisher
- Elsevier Science
- Year
- 1995
- Tongue
- English
- Weight
- 876 KB
- Volume
- 303
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
β¦ Synopsis
The electrochemical properties of carbon fibre microelectrodes (CFMES) are investigated in view of their application for the construction of amperometric biosensors based on oxidase enzymes. Scanning electron microscopy and cyclic voltammetry studies show that an appropriate electrochemical pretreatment has a strong effect on both morphology and electrochemical behaviour of the carbon fibre surface for all tested types of fibres. For AGT/F 10000 carbon fibres chosen for further study the surface becomes very smooth and a half-wave potential for H,O, oxidation assumes a reproducible value of about of +0.8 V vs. SCE. The electrochemistry of the ferro/ferricyanide redox system is irreversible and quasi-reversible on unpretreated and pretreated electrodes, respectively. In the latter case, however, the addition of 20 mM MgCl, or CaCl, to the buffer solution makes the cyclic voltammetry curves reversible. Using glucose oxidase as a model enzyme, a glucose microbiosensor is prepared by enzyme cross-linking onto the carbon fibre surface in glutaraldehyde vapour. When operating in a H,O, detection mode the biosensor dynamic range extends only up to about 2 mM glucose.
The deposition of additional membranes (a reticulated bovine serum albumin and Nafion film) on top of the enzyme layer allows an extension of the dynamic range up to 13 mM and substantial elimination of interferences. When ferricyanide is used as a soluble mediator the biosensor dynamic range extends up to 100 mM glucose. The biosensor response was stable at least for one month when it was stored in air or in a phosphate buffer (pH 7.4) at 4Β°C and used for about 30 measurements.
π SIMILAR VOLUMES
One-minimum U-shaped temperature profiles of the dissociation constant (K(m)) have been observed experimentally with a variety of enzyme-substrate (E-S) systems. The increase of E-S affinity with falling temperature ("positive thermal modulation of affinity"), which opposes the cold-induced reductio
## I51 sive wrinkling and corrugation. A disclination model seems to apply to the core of round filaments, the transitions from round to cracked structures imply disclination interactions along the length of the filament. 236. The textile prestretching of PAN-fibres as a controlling parameter for