𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Proof of principle: An HIV p24 microsphere immunoassay with potential application to HIV clinical diagnosis

✍ Scribed by Pascale Ondoa; Chris Vereecken; Eugene Lekeawung Asahchop; Amber Litzroth; Aziz Diallo; Katrien Fransen; Tandakha Dieye; Robin Ryder; Souleymane Mboup; Luc Kestens


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
263 KB
Volume
76B
Category
Article
ISSN
1552-4949

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The measurement of CD4 counts and viral loads on a single instrument such as an affordable flow cytometer could considerably reduce the cost related to the follow‐up of antiretroviral therapy in resource‐poor settings. The aim of this study was to assess whether the HIV‐1 p24 antigen could be measured using a microsphere‐based flow cytometric (FC) assay and the experimental conditions necessary for processing plasma samples. A commercial anti‐p24 antibody pair from Biomaric was used to develop a p24 microsphere immunoassay (MIA) using HIV culture supernatant as the source of antigen. The ultrasensitive Perkin Elmer enzyme immunoassay (EIA) served as a reference assay. Quantification of HIV p24 using the heat‐mediated immune complex disruption format described for plasma samples was feasible using the Biomaric MIA and applicable to a broad range of HIV‐1 Group M subtypes. The inclusion of a tyramide amplification step was successful and increased the fluorescence signal up to 3 logs as compared with the MIA without amplification. The analytical sensitivity of this ultrasensitive Biomaric assay reached 1 pg/mL, whereas the ultrasensitive Perkin Elmer EIA was sensitive to less than 0.17 pg/mL. Our data indicate, for the first time, that the principle of p24 detection using the heat‐denatured ultrasensitive format can be applied to FC. © 2008 Clinical Cytometry Society


📜 SIMILAR VOLUMES


Earlier diagnosis of HIV-1 infection by
✍ Seiichi Hashida; Kazuya Hashinaka; Ichiro Nishikata; Atsushi Saito; Akihisa Taka 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 616 KB

Serum samples of four HIV-1 seroconversion serum panels were subjected in a single assay tube simultaneously to ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) for p24 antigen of HIV-1 and for antibody lgGs to p17 and reverse transcriptase (RT) of HIV-1. Signals beca

Erratum: Hashida S, Hashinaka K, Ishikaw
📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 7 KB 👁 2 views

More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassa