𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Production of ultra-fine bioresorbable carbonated hydroxyapatite

✍ Scribed by R. Murugan; S. Ramakrishna


Publisher
Elsevier Science
Year
2006
Tongue
English
Weight
208 KB
Volume
2
Category
Article
ISSN
1742-7061

No coin nor oath required. For personal study only.

✦ Synopsis


Ionic-substituted hydroxyapatite (HAp) based materials may be a better choice than pure HAp owing to their similarity in chemical composition with biological apatite. The present study reports a process for the production of carbonated hydroxyapatite (CHAp) using microwaves. The CHAp was evaluated for its phase purity, chemical homogeneity, functionality, morphology, and solubility. The CHAp thus obtained was compared with a pure HAp and a biological apatite, which provides quite an interesting insight into the carbonate substitution. The in vitro ionic dissolution rates determined under physiological conditions clearly demonstrate the soluble nature of CHAp compared to HAp. The overall results indicate that the processed CHAp has increased resorption relative to pure HAp and has a chemical composition corresponding to some extent with that of biological apatite.


πŸ“œ SIMILAR VOLUMES


Carbonated hydroxyapatite nanopowders fo
✍ E. S. Kovaleva; M. P. Shabanov; V. I. Putlayev; Ya. Yu. Filippov; Y. D. Tretyako πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 345 KB

## Abstract Incorporation of carbonate ions to the crystal structure of carbonated hydroxyapatite (CHAp) leads to the formation of point defects (vacancies) in Ca‐ and OH‐sublattices as well as to microstrains revealed in CHAp nanocrystals. Various techniques, such as XRD, FTIR, TEM, FESEM/EDX, TG/

Solubility product of OH-carbonated hydr
✍ Ito, Atsuo ;Maekawa, Kentaro ;Tsutsumi, Sadao ;Ikazaki, Fumikazu ;Tateishi, Tets πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 173 KB

Information on the solubility of OH-carbonated hydroxyapatite, Ca10(PO4)6(CO3)x(OH)2-2x, previously has not been available. In the present study the solubility product (Ksp) of OH-carbonated hydroxyapatite was measured in a 0.1 M acetic acid and sodium acetate buffer solution in a pH range of 4.0-5.

Production of fine hydroxyapatite films
✍ Masahiro Kou; Takafumi Toda; Osamu Fukumasa πŸ“‚ Article πŸ“… 2008 πŸ› Elsevier Science 🌐 English βš– 485 KB

Hydroxyapatite (HAP)-coated implants on metallic substrates have been used as biomaterials. The problem is that HAP coating on metallic substrates is easily exfoliated at the boundary between HAP and metallic substrates, i.e. titanium (Ti). Therefore, Ti-HAP Functionally Graded Coating (FGC) is cons