𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Production of animal model of traumatic pseudoaneurysm

✍ Scribed by Hong-Tao Sun; Si-Zhao Liao; Hui Chen; Wen-Feng Feng; Yong-Nian Xu; Yu-Ming Zheng


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
356 KB
Volume
18
Category
Article
ISSN
0738-1085

No coin nor oath required. For personal study only.

✦ Synopsis


Three microsurgical techniques, i.e., electric cauterized vein patch (ECVP), electric cauterized vein segment (ECVS), and electric cauterized muscular cavity (ECMC), were employed to produce an ideal animal model of traumatic pseudoaneurysm (TPA). In this paper, 108 cases of TPAs were produced in rabbit femoral arteries. The successful rates of these microsurgical techniques, proved by angiography, autopsy in vivo, and histological examination, were 5.5, 16.7, and 88.9%, respectively. The successful rate of ECMC, with the merits of simple operation, a narrow neck but giant size of TPA which rarely ruptured, and the pulsatile mass occurring as early as 4 to 11 days after operation, was much higher than that of ECVP and ECVS (P < 0.01). By this reliable method of ECMC, the pathogenesis of TPA was observed as the following: the arterial wall was injured and partly ruptured, then the escaped blood was confined by fibrous connective tissue near the arterial opening. As a result, a located hematoma without any pulsatile mass and vascular systolic murmur formed. When a cavity occurred in the hematoma a few days later it gradually enlarged till the clot which plugged the arterial opening became so thin that arterial blood flowed into the cavity to form a pulsating hematoma. So, a pulsatile mass with vascular systolic murmur can be observed.


πŸ“œ SIMILAR VOLUMES


Studies on the animal model of traumatic
✍ Zheng Yuming; Xu Yongnian; Sun Yongtao; Huang Jifeng; Yang Shilin; Ke Changshu; πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 330 KB πŸ‘ 2 views

Sixty-nine cases of pseudoaneurysm were made in 72 femoral arteries of 54 Japanese white rabbits, with a successful rate of 95.8%. Colored Doppler's ultrasonic imaging, CT, MRI, arterial angiography, anatomic dissection, and histologic observation were carried out at different times after the operat

An animal model for the production of in
✍ Dr. Alvin Wald; Gerald M. Hochwald πŸ“‚ Article πŸ“… 1977 πŸ› John Wiley and Sons 🌐 English βš– 241 KB πŸ‘ 1 views

## Abstract This communication describes a reproducible model for the generation of intracranial pressure plateau waves by obstructing the spinal cord central canal of cats with experimentally induced hydrocephalus.

Animal Models of Addiction
✍ Willner, Paul (author) πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 133 KB πŸ‘ 1 views
Animal Models of Addiction
✍ Willner, Paul (author) πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 133 KB πŸ‘ 1 views
Animal models of tremor
✍ Hendrik Wilms; Jobst Sievers; GΓΌnther Deuschl πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 102 KB πŸ‘ 2 views

Animal models of tremor have been widely used in experimental neurology, because they are an indispensable requirement for understanding the pathophysiology of human tremor disorders and the development of new therapeutic agents. This review focuses on three approaches to produce tremor in animals (

Animal models of AIDS
✍ Dr. Maneth Gravell πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 169 KB πŸ‘ 2 views