Probe–Sample Coupling in the Magnetic Resonance Force Microscope

✍ Scribed by A. Suter; D.V. Pelekhov; M.L. Roukes; P.C. Hammel


Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
402 KB
Volume
154
Category
Article
ISSN
1090-7807

No coin nor oath required. For personal study only.

✦ Synopsis


The magnetic resonance force microscope (MRFM) provides a route to achieving scanned probe magnetic resonance imaging with extremely high spatial resolution. Achieving this capability will require understanding the force exerted on a microscopic magnetic probe by a spatially extended sample over which the probe is scanned. Here we present a detailed analysis of this interaction between probe and sample. We focus on understanding the situation where the micromagnet mounted on the mechanical resonator generates a very inhomogeneous magnetic field and is scanned over a sample with at least one spatial dimension much larger than that of the micromagnet. This situation differs quite significantly from the conditions under which most MRFM experiments have been carried out where the sample is mounted on the mechanical resonator and placed in a rather weak magnetic field gradient. In addition to the concept of a sensitive slice (the spatial region where the magnetic resonance condition is met) it is valuable to map the forces exerted on the probe by spins at various locations; this leads to the concept of the force slice (the region in which spins exert force on the resonator). Results of this analysis, obtained both analytically and numerically, will be qualitatively compared with an initial experimental finding from an EPR-MRFM experiment carried out on DPPH at 4 K.


📜 SIMILAR VOLUMES


Location of current carrying failure sit
✍ A. Pu; D.J. Thomson; G.E. Bridges 📂 Article 📅 2009 🏛 Elsevier Science 🌐 English ⚖ 384 KB

In integrated circuit failure analysis excessive current flow is often used to indicate the presence of faulty devices. By imaging the magnetic field produced by current flowing in integrated circuit conductors, these faulty devices can be located. Fault location by magnetic field imaging can be pro

The Bloch Equations in High-Gradient Mag
✍ W.M Dougherty; K.J Bruland; S.H Chao; J.L Garbini; S.E Jensen; J.A Sidles 📂 Article 📅 2000 🏛 Elsevier Science 🌐 English ⚖ 175 KB

We report theory and observations of paramagnetic resonance in a measured field gradient of 44,000 T per meter by the technique of magnetic resonance force microscopy (MRFM). Resonance was induced in a dilute solid solution of diphenylpicrylhydrazyl in polystyrene at 77 and 10 K by an amplitude-modu