𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Principles and applications of a dynamically focused phased array real time ultrasound system

✍ Scribed by Carlisle L. Morgan; William S. Trought; William M. Clark; Olaf T. von Ramm; Frederick L. Thurstone


Publisher
John Wiley and Sons
Year
1978
Tongue
English
Weight
999 KB
Volume
6
Category
Article
ISSN
0091-2751

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The physical principles and clinical applications of a high‐resolution, dynamically focused phased‐array real time ultrasound system are described. Advantages of the real time technique include rapid survey capability, efficient selection of an appropriate tomographic plane, identification of pulsating structures, and dynamic studies. The capabilities of a high resolution phased array with extended dynamic focusing to a range of 15‐20 cm are demonstrated in vascular, abdominal, and obstetric imaging. Appropriate clinical examples showing normal and pathological anatomy are presented. Comparisons with conventional B scans are illustrated.


πŸ“œ SIMILAR VOLUMES


Applications of real-time ultrasound in
✍ Carlisle L. Morgan; William S. Trought; Arthur Haney; William M. Clark πŸ“‚ Article πŸ“… 1979 πŸ› John Wiley and Sons 🌐 English βš– 730 KB

## Abstract Real‐time ultrasound is a dynamic imaging technique that allows in utero orientation to the fetus. It permits rapid and efficient examination of fetal anatomy and provides a dynamic assessment of fetal well‐being. The energy dissipation can be comparable to that in conventional ultrason

Real-time gesture recognition from dynam
✍ Takahiro Watanabe; Chil-Woo Lee; Masahiko Yachida πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 207 KB πŸ‘ 2 views

This paper discusses a method for real-time gesture recognition from a dynamic image and its application to an interactive system. The proposed technique enables a large volume of dynamic image information to be processed efficiently, by using a low-dimensional gesture space to represent a partial i

Ultrasound diagnosis of perforation of t
✍ Wing-Kay Chau; Andy-Tsuda Na; Teh-Tseng Feng; Yeou-Bing Li πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 268 KB

Perforation of the gallbladder can now be diagnosed in a noninvase fashion due to advent of gray-scale sonography. Conditions that may simulate gallbladder perforation in sonograms include pericholecystic fluid collection, ascites, pancreatitis, and peri t ~n i t i s . l -~ These signs, however, are

500-element ultrasound phased array syst
✍ Kullervo Hynynen; Gregory T. Clement; Nathan McDannold; Natalia Vykhodtseva; Ran πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 747 KB

The aim of this study was to test a prototype MRI-compatible focused ultrasound phased array system for trans-skull brain tissue ablation. Rabbit thigh muscle and brain were sonicated with a prototype, hemispherical 500-element ultrasound phased array operating at frequencies of 700-800 kHz. An ex v