𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Pressure relief consideration for refrigeration equipment

✍ Scribed by Joseph C. Leung


Publisher
American Institute of Chemical Engineers
Year
1996
Tongue
English
Weight
716 KB
Volume
15
Category
Article
ISSN
1066-8527

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Pressure relief sizing for refrigeration equipment is considered in this paper. In particular the ASHRAE fire sizing formula [2] is critically examined and comparisons are made with methods employed in other engineering institutes. The traditional sizing approach based on vapor relief is re‐exmained in light of the recent findings from the DIERS (Design Institute for Emergency Relief Systems) work [11]. The occurrence of two‐phase discharges during relief may result in significant overpresurization of the refrigeration equipment. The purpose of this paper is to suggest a methodology adequate for most designs and which has been verified with available experimental data.