𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Preface, Main Points, Introduction, Chapters 2 and 3

✍ Scribed by J. Valentin


Publisher
Elsevier Science
Year
2005
Tongue
English
Weight
59 KB
Volume
35
Category
Article
ISSN
0146-6453

No coin nor oath required. For personal study only.

✦ Synopsis


High-dose-rate brachytherapy is a rapidly growing technique (HDR) that has been replacing low-dose-rate (LDR) procedures over the last few years in both industrialised and developing countries. It is estimated that about 500,000 procedures (administration of treatment) are performed by HDR units annually. LDR equipment has been discontinued by many manufacturers over the last few years, leaving HDR brachytherapy as the major alternative. HDR brachytherapy techniques deliver a very high dose, of the order of 1.6-5.0 Gy/min, so mistakes can lead to under- or overdosage with the potential for clinical adverse effects. More than 500 HDR accidents (including one death) have been reported along the entire chain of procedures from source packing to delivery of dose. Human error has been the prime cause of radiation events. In the present report, the International Commission on Radiological Protection concludes that many accidents could have been prevented if staff had had functional monitoring equipment and paid attention to the results. Since iridium has relatively short half-life, the HDR sources need to be replaced approximately every 4 months. Over 10,000 HDR sources are transported annually, with the resultant potential for accidents; therefore, appropriate procedures and regulations must be observed. A number of specific recommendations on procedures and equipment are given in this report. The need for an emergency plan and for practising emergency procedures is stressed. The possibility of loss or theft of sources must be kept in mind. A collaborating team of specifically trained personnel following quality assurance (QA) procedures is necessary to prevent accidents. Maintenance is indispensable component of QA; external audits of procedures re-enforce good and safe practice, and identify potential causes of accidents. QA should include peer review of cases. Accidents and incidents should be reported and the lessons learned should be shared with other users to prevent similar mistakes.


πŸ“œ SIMILAR VOLUMES


Preface, Main Points, Chapters 1–6
✍ J. Valentine πŸ“‚ Article πŸ“… 2004 πŸ› Elsevier Science 🌐 English βš– 248 KB

Radioactive substances have been used in medicine for over 100 years. Today, medical use of radiation is the largest, and a growing, manmade source of radiation exposure. Nuclear medicine has become an important diagnostic and therapeutic specialty, and there are nearly 100 different procedures that

Preface, Main Points, Executive Summary,
✍ J. Valentin πŸ“‚ Article πŸ“… 2005 πŸ› Elsevier Science 🌐 English βš– 73 KB

This report aims to serve the purposes described above. In order to be as useful as possible for those purposes, its style differs in a few respects from the usual style of the CommissionΓ•s publications in the Annals of the ICRP. The report was approved for publication by the Commission in October

Guest Editorial, Preface, Main Points, G
✍ J. Valentin πŸ“‚ Article πŸ“… 2004 πŸ› Elsevier Science 🌐 English βš– 215 KB

Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overe