Potential errors in FTIR measurement of oxidation in ultrahigh molecular weight polyethylene implants
โ Scribed by Shen, Fu-Wen ;Yu, Yuh-Jeng ;McKellop, Harry
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 149 KB
- Volume
- 48
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
โฆ Synopsis
Potential sources of error in the use of FTIR to measure the level of oxidation in ultrahigh molecular weight polyethylene acetabular cups were evaluated using cups from a hip simulator wear study with and without artificial aging, as well as cups retrieved from clinically failed hip prostheses. Oxidation was measured as a function of depth below the bearing surface using transmission FTIR on microtomed sections of the cups. To account for the variation of the thickness of the microtomed sections, oxidation was plotted as the ratio of the absorbance of the carbonyl groups to the absorbance of a reference band at 2022 cm ุ1 . Overnight soaking in hexane reduced the apparent levels of oxidation, presumably due to the extraction of absorbed contaminants. In cups with low to moderate levels of oxidation, the reference absorption was relatively independent of the level of oxidation and was linearly proportional to the thickness of the specimens, providing reproducible oxidation ratios. However, the scatter in the reference absorption and in the apparent oxidation ratio increased with increasing levels of oxidation and was greatest for the thickest (400 m) microtomed sections. The profiles of the oxidation ratios for a given specimen that were plotted by the present study method could be numerically adjusted to coincide with the ratios plotted using the methods of two previous investigators, providing conversion factors that are useful for comparing results among the studies.
๐ SIMILAR VOLUMES
Flaking-type wear, so-called delamination, is often observed in polyethylene joint components. This is thought to occur partly due to crack formation and propagation at grain boundaries. This study examined the effect of vitamin E on the crack formation and/or propagation in UHMWPE by using 2-dimens
The mechanism resulting in damage to and failure of ultrahigh molecular weight polyethylene (UHMWPE) tibial inserts was investigated on clinically retrieved components. The severity of the subsurface damage increased with the length of time that the component had been implanted. A theoretical analys
Using a radiation peroxide grafting technique, a ultrahigh molecular weight polyethylene (UHMWPE) stored at room temperature for 10 days after irradiation in air was graft copolymerized with methyl methacrylate (MMA) in the presence of metallic salt and acid. The MMA-grafted UHMWPE samples were anal
A theoretical relationship was recently proposed relating the wear behavior of polymetric bearing materials articulating against hard counterfaces. 1 This model attempts to predict the influence of surface roughness on wear. Laboratory-based studies have been used to establish the validity of these
It is shown in this work that lubricant sorption in ultrahigh molecular weight polyethylene (UHMWPE) increases with available surface area of the component. This has clinical relevance, because sliding and articulation experienced in simulator studies can result in changes in surface roughness and t