๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses

โœ Scribed by Thomas P. Schmalzried; Murali Jasty; Andrew Rosenberg; William H. Harris


Publisher
Wiley (John Wiley & Sons)
Year
1994
Tongue
English
Weight
617 KB
Volume
5
Category
Article
ISSN
1045-4861

No coin nor oath required. For personal study only.

โœฆ Synopsis


Differences in bearing surface conformity and wear mechanisms suggest that the polyethylene (PE) wear debris generated by total knee replacement (TKR) prostheses should be different than that in total hip replacement prostheses (THR). To address this issue, PE wear debris and the cellular response in periprosthetic tissues from 19 failed TKRs was compared to that from 24 failed THRs using polarized light microscopy and a semiquantitative grading system. The foreign-body inflammatory reaction in the THR cases was characterized by plump macrophages with a diffuse cytoplasmic birefringence when examined under polarized light, indicating the presence of multiple submicron particles of PE. The majority of the PE particles were <1 pm in size and only a small fraction of the total were >10 pm. The foreign-body inflammatory reaction in the TKR cases was characterized by giant cells with fewer macrophages. In the TKR specimens, the size range of PE particles was broader than in the hips. PE particles between 2 and 20 pm were frequent in TKR specimens; particles <I pm in length were less common than in the THR specimens. Diffuse cytoplasmic birefringence was not a characteristic of the TKR cases. These histologic differences were so consistently distinct that the source of the specimen (i.e., from a THR or TKR) could be blindly determined by light microscopy. The size distribution of the PE wear particles in these cases indicate that THRs generate a higher number of submicron PE particles and relatively few large particles while TKRs generate a broader range of particles that includes fewer submicron particles. The observed differences in the cellular responses is likely a direct result of the differences in the spectrum of PE wear particles. These differences may in part account for differences in periprosthetic bone resorption and loosening in TKRs as compared to THRs.


๐Ÿ“œ SIMILAR VOLUMES


Tissue reactions to wear products from p
โœ Mathiesen, E. B. ;Lindgren, J. U. ;Reinholt, F. P. ;Sudmann, E. ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 788 KB

The tissue reaction to implanted materials and their wear products is important for the long-term fixation of a total hip replacement (THR). Recent reports indicate a relatively high incidence of aseptic loosening with Christiansen total hip prostheses. We examined tissue reactions to wear products

Shapes and dimensional characteristics o
โœ Schmalzried, Thomas P. ;Campbell, Pat ;Schmitt, Alexandra K. ;Brown, Ian C. ;Ams ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 162 KB ๐Ÿ‘ 1 views

Periprosthetic tissue was obtained at revision surgery from 10 posterior cruciate retaining total knee replacement cases (five different manufacturers). The tissues were hydrolyzed and polyethylene particles were isolated from each case. Individual particles were analyzed by scanning electron micros