𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Physical stability of salmon calcitonin spray-dried powders for inhalation

✍ Scribed by Hak-Kim Chan; Andrew R. Clark; Jane C. Feeley; Mei-Chang Kuo; S. Russ Lehrman; Katherine Pikal-Cleland; Danforth P. Miller; Reinhard Vehring; David Lechuga-Ballesteros


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
273 KB
Volume
93
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.

✦ Synopsis


The effects of excipient crystallinity and water content on the physical stability of salmon calcitonin (sCT) in a spray-dried powder for inhalation have been investigated. sCT was dissolved in water with and without mannitol and then spray dried using a Bu Β¨chi 190 spray dryer. The spray dried powders were stored for 5 days at 0, 29, 51, 58, 69, and 84% relative humidity at ambient temperature. The crystalline content, water content, secondary structure, and aggregation rates were determined for each powder immediately following spray drying and after storage at various relative humidities. In addition, the water sorption isotherms and reactivity to water vapor were determined using DVS and isothermal calorimetry, respectively. No sCT aggregation occurred during the spray drying process. Crystallinity depended on the amount of mannitol in the formulation. Powders containing up to 50% mannitol were fully amorphous, and those containing 70 and 90% mannitol contained some crystalline polyol. The powders remained aggregate free for over 2 years when stored below the critical RH (e.g., <20% for the powder containing 30% mannitol). Above this RH, sCT aggregation increased as a function of time. The amount of aggregate observed correlates with the amount of intermolecular b-sheet formed, determined by FTIR. The sCT aggregation rate in powders containing 70% mannitol was significantly lower than that in powders containing 30% mannitol at all RH tested, presumably because of a higher ratio of amorphous mannitol to sCT, which inhibits the formation of b-sheet structure. Moisture-induced crystallization of mannitol was observed in all powders stored at RH >50%. The moisture induced thermal activity trace (MITAT) offers a useful description on the physical stability of the spray dried powders. In conclusion, spray drying sCT and sCT/mannitol mixtures yields dry powders that contain physically intact peptide. In addition, sCT aggregation and mannitol crystallization in spray dried powders can be prevented during long-term storage if stored in low humidity environments, which can be easily assessed by MITAT.


πŸ“œ SIMILAR VOLUMES


Trileucine improves aerosol performance
✍ David Lechuga-Ballesteros; Chatan Charan; Cheryl L.M. Stults; Cynthia L. Stevens πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 688 KB

For particles to be useful medicinal aerosols, not only their aerodynamic diameter has to be on the order of a few micrometers but also they have to be chemically and physically stable. Manufacture of respirable particles is a technical challenge because as particles are reduced in size by conventio

Force control and powder dispersibility
✍ Claudius Weiler; Marc Egen; Michael Trunk; Peter Langguth πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 479 KB

This study aims towards a deeper understanding of the correlation between particle morphology, cohesion forces, and aerosol performance of spray dried powders for inhalation. Therefore, forces affecting cohesion and dispersion are considered and some novel contact models are introduced to explain th

Solid-state stability of spray-dried ins
✍ Negar Sadrzadeh; Danforth P. Miller; David Lechuga-Ballesteros; Nancy J. Harper; πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 381 KB πŸ‘ 1 views

The effect of temperature on the chemical stability of an amorphous spray-dried insulin powder formulation (Exubera) 1 was evaluated in the solid state at constant moisture content. The chemical stability of the powder was assessed using reversed-phase high-performance liquid chromatography (RP-HPLC