๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Photothermal bundle measurement of phantoms and blood as a proof of concept for oxygenation saturation measurement

โœ Scribed by Yonat Milstein; Michal Tepper; Moshe Ben David; James A. Harrington; Israel Gannot


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
245 KB
Volume
4
Category
Article
ISSN
1864-063X

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

This study objective is to validate a method for the measurement of two compound phantoms as a proof of concept for oxygen saturation level measurement via a thermal imaging bundle. The method consists of a thermal imaging system and an algorithm which estimates the compound concentration according to temperature rise. A temperature rise is obtained by illuminating the tissue with a laser with different wavelengths in the NIR range and measured using a thermal camera. A coherent thermal imaging bundle was used for image transmittance for minimal invasive transendoscopic use. The algorithm's estimation ability was evaluated using agar phantoms of varying Methylene Blue and ICG ratios as well as blood samples The Methylene Blue ratio in each phantom was estimated and the calculated average RMS of the error was 9.38%, a satisfying value for this stage, verifying the algorithm's and bundle's suitability for the use in a minimal invasive system. (ยฉ 2011 WILEYโ€VCH Verlag GmbH & Co. KGaA, Weinheim)


๐Ÿ“œ SIMILAR VOLUMES


In vivo measurement of blood oxygen satu
โœ E. Mark Haacke; Song Lai; Jรผrgen R. Reichenbach; Karthikeyan Kuppusamy; Frank G. ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 145 KB ๐Ÿ‘ 2 views

A novel noninvasive magnetic resonance imaging (MRI) method was developed to determine in vivo blood oxygen saturation and its changes during motor cortex activation in small cerebral veins. Specifically, based on susceptibility measurements in the resting states, pial veins were found to have a mea

Measuring the human retinal oxygenation
โœ Bruce A. Berkowitz; Christopher McDonald; Yasuki Ito; Paul S. Tofts; Zahid Latif ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 208 KB

## Abstract The retinal oxygenation response to a hyperoxic challenge measured using MRI appears to be an early and accurate marker of retinopathy risk in experimental models, with promising clinical potential. However, the application of this technique in humans is limited by blinking artifacts th

Accuracy of phase contrast, black-blood,
โœ Valentina Taviani; Andrew J. Patterson; Pauline Worters; Michael P.F. Sutcliffe; ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 351 KB

## Abstract ## Purpose: To assess the accuracy of MRโ€derived luminal diameter variations and its implications for compliance (CC) and distensibility coefficients (DC) by comparison with highโ€resolution digital photography (HRDP) in a tissueโ€mimicking phantom with pulsatile flow. ## Materials and

Ultrasonic measurement of fetal blood ve
โœ Karel Marลกรกl; Per-Hรฅkan Persson ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 567 KB

Based on routine fetometry screening a t 32 weeks of gestation, 80 out of 3226 singleton pregnancies were suspected of intrauterine growth retardation (IUGR) and 72 of them were subjected to repeated fetal blood flow measurements by Doppler ultrasound for evaluation of the fetal condition. The maxim